HWACLMAN Messages

This section contains the hardware ACL Manager (HWACLMAN) messages.
Error Message C4K_HWACLMAN-4-ACLHWPROGERR:[input/output]
limit,
Error Message C4K_HWACLMAN-4-ACLHWPROGERRREASON:[input/output]
[char] -
Error Message C4K_HWACLMAN-4-CAMAUDIT: ACl/QOS CAM Health Check: [input/output]
[char] Index:
Error Message C4K_HWACLMAN-4-CAMBLOCKMASKALLOCFAILED: CAM state memory allocation
failure in region [dec]
Error Message C4K_HWACLMAN-4-CLASSIFCAMPARITYERROR: Parity error detected in
[input/output]
OL-11541-01
[char]
Some ACL-based features cannot be fully programmed into the hardware. Packets that
Explanation
use these features complete processing in the software. If the feature is a policy map, then QoS is
completely disabled (on the specific interface).
This message lists the impacted feature; further messages list the specific failure that occurred.
This is an informational message only. No action is required.
Recommended Action
[char]
This message provides a specific failure that prevented ACL-based features from being
Explanation
fully programmed into the hardware.
This is an informational message only. No action is required.
Recommended Action
[dec] [char] ( Cumulative Error Count: [dec] )
The background system health monitor detected a potential problem.
Explanation
If this is a software error, the system has already corrected itself automatically
Recommended Action
and no action is required. If this is a hardware error, power cycle the switch.
The software could not allocate memory to maintain a software copy of the hardware
Explanation
classification TCAM masks that are used for ACL and QoS functionality.
This condition should never occur. If you see this message, copy it exactly and
Recommended Action
contact your technical support representative.
Classification CAM
The system detected and fixed a parity error in the hardware. If you see this error
Explanation
repeatedly, there is a strong likelihood of a hardware fault and the supervisor engine will need to be
replaced.
The software fixes the parity error by rewriting the CAM entries to the
Recommended Action
hardware. If the problem persists, contact your technical support representative.
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
[char] - hardware TCAM
[char] Cell
[object-info] and corrected
HWACLMAN Messages