IOSSYS Message
Error Message C4K_IOSSYS-3-SAVEPOSTRESULTFAILED: Failed to save POST results to
[char]. [char].

IOSSYS-4

Error Message C4K_IOSSYS-4-BLANKPRIVATECONFIG: Blank or invalid private-config

IOSSYS-7

Error Message C4K_IOSSYS-7-INVALIDVALUE: [char] Type [dec] not handled returning a
default of 0
Error Message C4K_IOSSYS-7-SETENVERR: Failed to set environment variable: [char].
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
2-58
The system cannot save the POST results to bootflash because the bootflash memory
Explanation
might be full.
Check if the bootflash memory is full. If the bootflash memory is full, delete
Recommended Action
the old POST results by entering the delete \force post* and the squeeze bootflash: commands.
An invalid private-config is found in the NVRAM, or the private-config was missing.
Explanation
Recommended Action
If this message comes up after a software upgrade, try saving the configuration
again and reboot the switch. If the message goes away in the next boot, then it can be ignored. If this
message displays each time that the switch is rebooted, contact your technical support
representative.
This message is used by developers only and should not occur during customer
Explanation
operation.
Contact your technical support representative.
Recommended Action
The system cannot write the specified environment variable because the bootflash
Explanation
memory or NVRAM has insufficient memory.
Recommended Action
Clear the unnecessary environment variables by entering the clear platform