Remote Voltage Programming Of Output Voltage And Output Current - TDK-Lambda GENESYS 750W User Manual

Programmable dc power supplies
Hide thumbs Also See for GENESYS 750W:
Table of Contents

Advertisement

6.4

Remote Voltage Programming of Output Voltage and Output Current

To maintain the power supply isolation and to prevent ground loops, use an isolated
programming source when operating the power supply via remote analog
programming at the J1 connector.
Perform the following procedure to set the power supply to Remote Voltage programming:
1. Turn the power supply AC On/Off switch to Off.
2. Set setup switch SW1, positions 1 and 2 to their UP position.
3. Set SW1, position 3 to select the programming voltage range according to Table 6-3.
4. Ensure that SW1, positions 7 and 8 are at their DOWN (default) position.
5. Connect a wire jumper between J1-8 and J1-12 (refer to Table 4-4).
6. Connect the programming source to the mating plug of J1 as shown in Fig.6-1. Observe
correct polarity for the voltage source.
7. Set the programming sources to the desired levels and turn the power supply ON. Adjust
the programming sources to change the power supply output.
NOTES:
SW1, positions, 4, 5, 6 and 9 are not required for remote programming. Their settings can
be determined according the application.
The control circuits allow the user to set the Output Voltage and Output Current up to 5%
over the model-rated maximum value. The power supply will operate within the extended
range, however it is not recommended to operate the power supply over its voltage and
current rating, and performance is not guaranteed.
Table 6-3: SW1-3 setting and programming range
SW1-3 setting
UP
DOWN
Output Voltage programming
VPGM (J1-9)
0-10V
0-5V
J1 connector, rear panel view
OUTPUT CURRENT
PROGRAMMING
+
12
10
9
13
25
23
22
Fig.6-1: Remote voltage programming connection
83507013 Rev G
CAUTION
Output Current programming
IPGM (J1-10)
OUTPUT VOLTAGE
PROGRAMMING
+
8
1
14
71
0-10V
0-5V