SPECIFICATION

Max. Air Pressure:
Max. Fluid Pressure:
Cylinder Air Pressure:
Weight:
Gun Stud Diameter:
Fluid Thread:
CYL Thread:

INSTALLATION

Figure 1. Dimensions
Mount the gun with the set screw (22).
NOTE:
The air supplied to the gun should be clean air that removed any impurities. Also, the air hose
should have enough inner diameter depending on the length to supply necessary air.
OPERATIONS
1. Mix, prepare and strain the coating material to be sprayed according to paint manufacture's instructions.
2. Adjust the CYL air at 0.35 Mpa ~. Please use air regulator for setting the air pressure for the smooth
movement of CYL.
3. Turn Needle Adjusting Knob counter-clockwise 3.5 turns from fully closed position. This makes the Needle
fully opened.
4. Adjust CAP air at 0.20Mpa.
5. Adjust fluid pressure at about 0.07Mpa~0.1Mpa.
6. Turn on CYL air and test spray. Adjust fluid and air pressure until desired pattern is obtained. Pattern size
can be adjusted by using pattern valve (5). Control fluid pressure at supply source. Always attempt to
keep CAP pressure as low as possible to minimize overspray and control the air at air supply source.
WARNING
Risk of injury. Equipment and fluid may be under pressure. Pressure in the system must be
relieved before beginning the cleaning procedure and before replacing any parts. Follow the
procedures in the literature provided with the system.
0.69MPa (6.9 bar)
0.69MPa (6.9 bar)
Min. 0.35MPa (3.5 bar)
Max. 0.50MPa (5.0 bar)
480g
16.0mm
G1/4 (M)
CAP Thread:
G1/4 (M)
4
G1/4 (M)