Specifications

Alarm Port

The dry relay alarm port operates up to 50V AC/DC maximum and up to 80 mA maximum. Total power
dissipation should not exceed 300 milliwatts. The normally closed position will have from 15 to 30 ohms
resistance. The open position will be greater than 1 megohm. The Alarm condition is the closed position.
This port is a switch so that the cable connector can be inserted in either orientation.

Lithium Battery Caution

This caution is required although the Cisco 7401ASR router has no internal field replaceable units.
Caution
ADVARSEL!
VAROITUS
ADVARSEL
VARNING
OL-5419-01 B0
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer. Dispose
of used batteries according to the manufacturers instructions.
Lithiumbatteri - Eksplosionsfare ved fejlagtig håndtering. Udskiftning
må kun ske med batteri af samme fabrikat og type. Levér det brugte
batteri tilbage tilleverandøren.
Paristo voi räjähtää, jos se on virheellisesti asennettu. Vaihda paristo
ainoastaan valmistajan suosittelemaan tyyppiin. Hävitä käytetty paristo
valmistajan ohjeiden mikaisesti.
Eksplosjonsfare ved feilaktig skifte av batteri. Benytt samme batteritype
eller en tilsvarende type anbefait av apparatfabrikanten. Brukte batterier
kasseres i henhold til fabrikantens instruksjoner.
Eksplosionsfara vid felaktigt batteribyte. Använd samma batterityp eller
en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera
använt batteri enligt fabrikantens instruktion.
Cisco 7401ASR Installation and Configuration Guide

Alarm Port

A-9

Advertisement

Table of Contents
loading

Table of Contents