Cisco Nexus 7000 Series Hardware Installation And Reference Manual page 103

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Chapter 6
Managing the Device Hardware
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
Full redundancy mode—Provides both power-supply redundancy and input-source redundancy.
This mode lets you replace a power supply without interrupting system operations or continue
powering the device if one of two grids goes down. The available power is the lesser amount of
output power for power supply redundancy or input source redundancy.
To determine the amount of available power for 6-kW power supply units in each power mode, see
Table
Table 6-1
Dual inputs per power supply unit
220-V and 220-V inputs
220-V and 110-V inputs
110-V and 110-V inputs
Single inputs per power supply unit
220-V input
110-V input
OL-18634-01
6-1. To determine the amount of available power for 7.5-kW power supply units, see
Power Availability for 6-kW Power Supply Units
1 power supply
2 power supply units
3 power supply units
1 power supply
2 power supply units
3 power supply units
1 power supply
2 power supply units
3 power supply units
1 power supply
2 power supply units
3 power supply units
1 power supply
2 power supply units
3 power supply units
Power
Supply
Combined
Redundancy
Mode
Mode
6000 W
12,000 W
6000 W
18,000 W
12,000 W
4200 W
8400 W
4200 W
12,600 W
8400 W
2400 W
4800 W
2400 W
7200 W
4800 W
3000 W
6000 W
3000 W
9000 W
6000 W
1200 W
2400 W
1200 W
3600 W
2400 W
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
Power Supply Configuration Modes
Table
6-2.
Input Source
Full
Redundancy
Redundancy
Mode
Mode
3000 W
6000 W
6000 W
9000 W
9000 W
1200 W
2400 W
2400 W
3600 W
3600 W
1200 W
2400 W
2400 W
3600 W
3600 W
6-9