Information About Fan Trays - Cisco Nexus 7000 Series Hardware Installation And Reference Manual

Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

Information About Fan Trays

S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
DETAILED STEPS
Command
Step 1
config t
Example:
switch# config t
switch(config)#
Step 2
poweroff module slot_number
Example:
switch(config)# poweroff module 1
switch(config)#
no poweroff module slot_number
Example:
switch(config)# no poweroff module 1
switch(config)#

Information About Fan Trays

Hot-swappable fan trays are provided in all devices in the Cisco Nexus 7000 Series to manage airflow
and cooling for the entire device. Each fan tray contains multiple fans to provide redundancy. The device
can continue functioning in the following situations:
If one or more fans fail within a fan tray, the Fan Status LED turns red. A fan failure could lead to
Tip
temperature alarms if not corrected immediately.
The fan status is continuously monitored by the software. In case of a fan failure, these actions occur:
Use the show environment fan command to display the fan module status (see
Example 6-8
switch# show environment fan
------------------------------------------------------
Fan
------------------------------------------------------
Chassis
PS-1
PS-2
Cisco Nexus 7000 Series Hardware Installation and Reference Guide
6-24
One or more fans fail within a fan tray—Even with multiple fan failures, the Cisco Nexus 7000
Series device can continue functioning. When a fan fails within a tray, the functioning fans in the
module increase their speed to compensate for the failed fans.
The fan tray is removed for replacement—The fan tray is designed to be removed and replaced while
the system is operating without presenting an electrical hazard or damage to the system. When
replacing a failed fan tray in a running system, be sure to promptly replace the fan tray.
System messages are displayed.
Call Home alerts are sent (if configured).
SNMP notifications are sent (if configured).
Displays Chassis Fan Information
Model
DS-9SLOT-FAN
--
--
Chapter 6
Purpose
Enters configuration mode.
Powers off the specified module (fabric module 1) in the
device.
Powers up the specified module (fabric module 1) in the
device.
Hw
Status
1.2
ok
--
ok
--
absent
Managing the Device Hardware
Example
6-8).
OL-18634-01