VKI Technologies Eccellenza Café Operating Manual page 84

Vki technologies eccellenza café coffee machine operating manual
Table of Contents

Advertisement

Eccellenza Café – Operating Manual
MESSAGE DISPLAYED
Factory Settings
Version Error
Filling Water Tank
Finding Brewer Home
Heating Water
LCD Error
Money System Error
Overflow Error
Overheat Error
PnB not Detected
Port J10 Not Detected
Port J23 Not Detected
Powersaving Mode –
Press Start to Exit
84
CAUSE
The version of Factory
Settings is not compatible
with the machine model.
Water tank is filling
Brewer is cycling to find
the home (starting)
position.
Water inside the hot
water tank is heating
An error has been
detected with the LCD
display.
The coin changer is not
being detected.
A water overflow has
been detected.
The water tank is
overheating.
The control board is not
being detected.
Wiring harness is
disconnected from port 10
on the control board.
Wiring harness is
disconnected from port 23
on the control board.
The machine is in
Powersaving Mode.
March 3, 2014
POSSIBLE REMEDIES
Load the proper version of Factory
Settings.
Normal operating message and does
not indicate an error.
Normal operating message and does
not indicate an error.
Normal operating message and does
not indicate an error.
Verify the wiring connections to the
LCD display.
Replace the LCD display.
Verify the wiring connections at the
control board and inside the changer
unit.
Replace the defective coin changer.
Empty and dry the overflow/cup tray.
Verify the water level probe
adjustment. They may be set too high
allowing too much water into the tank.
Water level probes may need to be
cleaned.
Inlet valve may be leaking,
constantly allowing water to enter the
tank. Replace the inlet valve.
Water in the tank may be boiling.
Lower the water temperature setting.
Check the temperature settings in
the set-up.
The temperature probe may need to
be replaced.
The USB cable is not connected to
the control board or the expansion
board. Verify the connections.
Reconnect the wiring harness to port
10 on the control board.
Reconnect the wiring harness to port
23 on the control board.
Press the Start button to exit
Powersaving Mode.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents