NOTE: For multi-unit locations whereby the main water conduit is supplying
water to more than one unit (including water coolers), a separate in-line
shut off valve must be installed onto each individual equipment unit.
4. Water Fittings & Valves - Material Requirements (Conforms to NSF-51 & NSF-61):
Fittings & valves (water supply connection - water filter head - brewing equipment):
► NSF CONFORMING: BARB type fittings with OERTIKER clamps
► PREFERENCE: Custom nickel plated brass
► ALTERNATE: Stainless Steel (much more costly)
NOTE: Water cooler equipment arriving pre-fitted with quick connect type fittings
must have them replaced by approved fittings prior to being installed at
customer location(s).
Quick-connect type fittings are not approved for use with any VKI
manufactured equipment.
MATERIAL REQUIREMENTS:
E
T
UBING
T
UBING
NOTE: The shut-off valve must be easily
accessible by the customer, who
must be informed of its location
during the installation.
F
: Male 3/8 inch NPTF
QUIPMENT
ITTING
(W
ATER SUPPLY TO FILTER
(W
ATER FILTER TO EQUIPMENT
): Reinforced PVC Beverage grade
): Stainless steel braided hose