Installing Netcam Sc To Pipe/Wall/Ceiling - StarDot Technologies NetCam SC User Manual

Vandal resistant dome camera
Hide thumbs Also See for NetCam SC:
Table of Contents

Advertisement

Separate Ethernet and Power
If you decide not to use PoE, you can connect one end of a CAT
5 or better Ethernet cable into a hub/switch and the other end into the
NET jack on the back of NetCam SC. Plug a 12VDC 1A power supply
into the back of NetCam SC (or you may use a 24VAC power supply
and connect it to the input marked 24VAC).
StarDot's Power/Network Cable
If you choose not to power NetCam SC via PoE and you still want the
take advantage of a single cable run, StarDot provides Power/Network
cable that allows you to run both power and data in the same cable. Visit
http://www.stardot.com for more information.
2.2

Installing NetCam SC to Pipe/Wall/Ceiling

NOTE: To maintain IP66 weatherproofing, make sure to close up all unused
mounting holes with the provided screws and O-rings.
Use the shown holes [A] in figure 1 if you are mounting the dome
directly to a ceiling or wall.
Use the shown holes [B] in figure 1 if you are mounting the
dome directly to a wall mount adapter (Wall mount adapter not
included).
Use the shown holes [C] in figure 1 if you are mounting the dome
directly to a junction box (Junction box and gasket not included).
Page 12
NetCam SC Vandal Resistant Dome