Through connectivity provided by the fabric switches, all hosts again have access to the
required data.

8.7.3 MetroCluster interconnect failure

In this scenario, the fabric switch interconnects have failed (Figure 8-16). Although this is not
a critical failure, resolve it promptly before a more critical failure occurs.
Figure 8-16 Interconnect failure
During this period, data access is uninterrupted to all hosts. No automated controller takeover
occurs. Both controller heads continue to serve its LUNs/volumes. However, mirroring and
failover are disabled, thus reducing data protection. When the interconnect failure is resolved,
resyncing of mirrors occurs.
120