Slide the lightpipe out of the chassis.
5.
To replace the component, reverse the removal procedure.

Power converter module

To remove the component:
Power down the server (on page 20).
1.
Extend or remove the server from the rack
2.
the server from the
Remove the access panel
3.
Remove the front fan bracket
4.
IMPORTANT: For this procedure, you do not need to remove the hot-plug fans from the front fan bracket.
When reinstalling the front fan bracket, press the top of each fan to be sure it seats securely.
Remove all hot-plug power supplies
5.
Disconnect all power cables.
6.
Remove the power converter module.
7.
("Extend the server from the
rack" on page 20).
("Access
panel" on page 22).
("Front fan
bracket" on page 25).
("Hot-plug power
rack" on page 19,
supply" on page 47).
Removal and replacement procedures 36