Non-Hot-Plug Procedures; Access Panel; Dvd/Cd-Rom Drive - HP DL380 Generation 4 Maintenance And Service Manual

Generation 4 server
Table of Contents

Advertisement

To close the cable management arm, reverse this procedure.

Non-hot-plug procedures

Access panel

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and
the internal system components to cool before touching them.
CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating
the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.
To remove the component:
Power down the server if performing a non-hot-plug installation or maintenance procedure
1.
down the
Extend the server from the rack, if applicable
2.
Lift up on the hood latch handle and remove the access panel.
3.
To replace the component, reverse the removal procedure.

DVD/CD-ROM drive

To remove the component:
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays
are populated with either a component or a blank.
Power down the server (on page 20).
1.
IMPORTANT: The ejector button is recessed to prevent accidental ejection; it may be helpful to use a pen
or similar shaped object to access the button.
Remove the drive.
2.
To replace the drive, slide the drive into the bay until the drive is fully seated.
server" on page 20).
("Extend the server from the
Removal and replacement procedures 22
("Power
rack" on page 19).