Trouble Shooting - Emerson ASHLAND CF717BS00 Owner's Manual

52” ceiling fan, brushed steel, oil rubbed bronze, satin white,
Hide thumbs Also See for ASHLAND CF717BS00:
Table of Contents

Advertisement

BP7483 ASHLAND CF717
12/19/13
!
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLE SHOOTING YOUR FAN.
TROUBLE
1. Fan will not start.
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan,
3. Reversing switch in neutral position.
2. Fan sounds noisy. 1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Wire connectors inside switch housing
4. Screws holding blades to flywheel
3. Fan wobbles
1. Setscrews in motor coupling are loose.
excessively.
2. Setscrew in hanger ball/downrod
3. Screws securing fan blades to
4. Hanger bracket and/or ceiling outlet
5. Fan blades out of balance.
1. Loose electrical connectors.
4. Lamps will not
illuminate.
2. The lamps are burnt out.
3. Lamps turns on and then turns off.
9:59 AM
Page 19

15. Trouble Shooting

PROBABLE CAUSE
or loose switch wire connections in the
switch housing.
rattling.
are loose.
assembly is loose.
flywheel are loose.
box is not securely fastened.
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit
breakers.
2. Check line wire connections to fan and switch
wire connections in the switch housing.
WARNING: Make sure main power is turned OFF.
!
3. Make sure reversing switch position is all the
way to one side.
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing
are snug (not over-tight).
3. Check to make sure wire connectors in switch
housing are not rattling against each other or
against the interior wall of the switch housing.
WARNING: Make sure main power is turned OFF.
!
4. Tighten screws securely.
1. Tighten both setscrews securely in the motor
coupling.
2. Tighten the setscrew in the hanger ball/
downrod assembly.
3. Check to be sure screws which attach the fan
blades to the motor are tight.
4. Tighten the hanger bracket screws to the outlet
box, and/or secure outlet box.
5. Interchanging an adjacent (side-by-side) blade
pair can redistribute the weight and result in
smoother operation.
1. Shut off the branch circuit electricity at the fuse box or breaker.
panel and check the receiver electrical connectors for proper
installation.
2. Turn the electricity off and replace the lamp with a new 60W
maximum lamp.
3. The build in circuit breaker is tripping. Check that each lamp is
60W maximum.
Please contact 1-800-654-3545 for further assistance
19
emersonfans.com
ETL Model No.: CF717

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ashland cf717orb00Ashland cf717sw00

Table of Contents