Trouble Shooting - Emerson CF717BS01 Owner's Manual

Table of Contents

Advertisement

BP7483-2 ASHLAND CF717.qxp_BP7483 12/15/15 9:55 AM Page 23
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
!
TROUBLE SHOOTING YOUR FAN.
TROUBLE
1. Fan will not start.
2. Fan sounds noisy.
3. Fan wobbles
excessively.
4. Lamps will not
illuminate.

16. Trouble Shooting

PROBABLE CAUSE
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan,
or loose switch wire connections in the
switch housing.
3. Reversing switch in neutral position.
1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Wire connectors inside switch housing
rattling.
4. Screws holding blades to flywheel
are loose.
1. Setscrews in motor coupling are loose.
2. Setscrew in hanger ball/downrod
assembly is loose.
3. Screws securing fan blades to
flywheel are loose.
4. Hanger bracket and/or ceiling outlet
box is not securely fastened.
5. Fan blades out of balance.
1. Loose electrical connectors.
2. The lamps are burnt out.
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit
breakers.
2. Check line wire connections to fan and switch
wire connections in the switch housing.
WARNING: Make sure main power is turned OFF.
!
3. Make sure reversing switch position is all the
way to one side.
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor housing
are snug (not over-tight).
3. Check to make sure wire connectors in switch
housing are not rattling against each other or
against the interior wall of the switch housing.
WARNING: Make sure main power is turned OFF.
!
4. Tighten screws securely.
1. Tighten both setscrews securely in the motor
coupling.
2. Tighten the setscrew in the hanger ball/
downrod assembly.
3. Check to be sure screws which attach the fan
blades to the motor are tight.
4. Tighten the hanger bracket screws to the outlet
box, and/or secure outlet box.
5. Interchanging an adjacent (side-by-side) blade
pair can redistribute the weight and result in
smoother operation.
1. Shut off the branch circuit electricity at the fuse box or breaker.
panel and check the receiver electrical connectors for proper
installation.
2. Turn the electricity off and replace the lamp with a new lamp.
Please contact 1-800-654-3545 for further assistance
23
emersonfans.com
ETL Model No.: CF717-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf717orb01Cf717sw01

Table of Contents