Download Print this page

Adjustment Procedure - Epson Stylus PhotoR280 Service Manual

Epson stylus photo color inkjet printer service manual

Advertisement

EPSON Stylus Photo R280/R285/R290

5.3.2 Adjustment Procedure

5.3.2.1 BRS (Banding Reduction System) Adjustment
Printing the BRS Adjustment Pattern
1.
Load A4 size Matte Paper-Heavyweight on the paper support.
2.
Select [BRS Adjustment] in the adjustment program.
3.
Click the [Print] button on the "1. Print Test Pattern" column to print the
adjustment pattern.
4.
Let the printed pattern dry for more than 5 minutes if using CIS sensor type
scanner.
Figure 5-13. BRS Test Pattern
In the Adjustment program, the identification code is used to
distinguish whether the printer that printed the pattern and the
printer to register the adjustment value is the same.
Make sure to let the printed pattern dry for more than 5
minutes if using CIS sensor type scanner. When using CCD
sensor type scanner, the printed pattern does not need to be
dried before scanning. Refer to
for BRS/PFP Adjustment" (p.107)
Chapter 5 Adjustment
5.3 Banding Reduction System (BRS) Adjustment / Paper Feed Amount Profile (PFP) Correction
Printer Identification
Code
"Table 5-7. Specified Scanner
Scanning the BRS Adjustment Pattern
5.
Set the printed pattern and the PFP Base Scale on the document table and click the
[Scan] button on the "3. Scan Test Pattern" column.
6.
According to the scanned result, BRS calibration values are automatically
calculated and are written to the serial flash ROM. If an error occurs, check that
the document table glass and the scale is clean, and the scale/adjustment pattern is
not tilted, then repeat from step 5.
Be careful of the following when setting the PFP Base Scale, and
the adjustment pattern on the scanner.
Place the scale on the document glass aligning the scale corner
with the scanner origin position.
Place the pattern-printed sheet along the scale as shown in the
figure below. Make sure to place it parallel to the scale, with
no gaps.
Scanner Origin
Position
PFP Base Scale
Figure 5-14. PFP Base Scale and BRS Adjustment Pattern Position
(Viewed from the document glass of the scanner)
Revision B
BRS Adjustment
Pattern (A4)
Scanner Document
Table
109

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Stylus photo r285Stylus photo r290Stylus photo r280