Epson WF-5690/4640/4630/5620/5190/5110 series

3.2.3.2 Adjustment Procedure

 The head angular adjustment has two kinds of adjustment method.
• Using the particular scanner
• Using the visual adjustment pattern
 In this adjustment, make sure to set the dial at the origin position with the follows before
perform the Head angular adjustment.
Top
 Tool
Specified Scanner for Head Angular Mechanism Adjustment : Perfection V600 Photo / V550 Photo
 Method of the Head angular adjustment.(Using the particular Scanner)
1. Start the product in the "Printer Inspection Mode" in accordance with
Angular Adjustment
2. Select the "Head angular mecha adjustment" from menu of adjustment program, and print the head angular
adjustment pattern
Adjustment
Figure 3-9. Origin position of the adjustment dial
(p60)".
Figure 3-10. Procedure of the Head Angular Adjustment (1)
Details of Adjustments
Right side
Bold line is origin position ("0" position)