Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Omega Manuals
Temperature Controller
CN63100 Series
User manual
Configure Module 2 - Output Parameters (2-Op) - Omega CN63100 Series User Manual
1/16 din temperature/process controllers
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
page
of
92
Go
/
92
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Enlarged version
Configure Module 2 - Output Parameters (2-OP)
Range and Units
Display
Parameter
(Factory Setting)
CYCt
Time
0 to 250 seconds
Proportioning
(2)
Cycle Time
OPAC
Output Control
drct - cooling
Action
rEv - heating
(rEv)
OPLO
Output Power
0% to 100%, O1
Lower Limit
(0)
(Not used in
-100% to 100%,
Manual Control)
O1 & O2
(-100)
OPHI
Output Power
0% to 100%, O1
Upper Limit
(100)
(Not used in
-100% to 100%
Manual Control)
O1 & O2
(100)
OPFL
Sensor Fail
0% to 100%, O1
Power Level
(0)
(Not used in
-100% to 100%
Manual Control)
O1 & O2
(0)
OPdP
Output Power
0 to 250 seconds
Dampening
(3) CN63100
(filtering) Time
(1) CN63300
Description/
Comments
0 turns O1 off. Set to
zero for Linear DC
output control. Not used
for ON/OFF Control.
For both PID & ON/OFF
control.
Set OPLO < OPHI
Negative % is only valid
for O2 cooling control.
Set OPHI > OPLO
Negative % is only valid
for O2 cooling control.
Select a level to safely
control the process in
the event of input
sensor failure.
CN63100 only.
0 = off (no dampening)
Set in range of 1/50 to
1/10 of integral time.
Adjusted by Auto-Tune.
-22-
Display
Parameter
CHYS
ON/OFF Control
Hysteresis
tcOd
Auto-tune
Dampening Code
ANtP
Main Linear DC
Output Range *
ANAS
Main Linear DC
Output Source *
ANUt
Main Linear DC
Output Update *
ANLO
Main Linear DC
Output Low Scaling
Value *
ANHI
Main Linear DC
Output High
Scaling Value *
* Model Number Dependent
Range and Units
Description/
(Factory Setting)
Comments
1 to 250
For O1 ON/OFF
(2) CN63100
Control. Change to
(0.2) CN63300
Factory Setting prior
to Auto-Tune.
0 to 2
0 = fastest response
(0)
2 = slowest response
0 to 10 V
Set linear output
0 to 20 mA
range jumper to
4 to 20 mA
match.
(4 to 20 mA)
OP
SP = Active Setpoint
InP
SP
(OP)
0 to 250 secs
0 = Update rate of 0.1
(0)
sec.
-999 to 9999
Value depends on
(0.0)
ANAS assignment.
-999 to 9999
Value depends on
(100.0)
ANAS assignment.
Table of
Contents
Previous
Page
Next
Page
1
...
27
28
29
30
31
32
33
34
Advertisement
Table of Contents
Troubleshooting
Abbreviated Controller Transmission Byte Format
72
TROUBLESHOOTING
79
Related Manuals for Omega CN63100 Series
Temperature Controller Omega CNi8 Manual
I-series temperature & process controller manual (72 pages)
Temperature Controller Omega C9000A SERIES User Manual
Autotune temperature controller (92 pages)
Temperature Controller Omega CN1001-RTD User Manual
(64 pages)
Temperature Controller Omega CN710 Instruction Sheet
(2 pages)
Temperature Controller Omega CN76000 Manual
(54 pages)
Temperature Controller Omega CN1000-RTD Quick Start
Temperature controller with time proportional control (2 pages)
Temperature Controller Omega CN616TC1 User Manual
Cn616 series 1/4 din economical 6-zone pid temperature controllers (28 pages)
Temperature Controller Omega FUZZY LOGIC CN4800 Manual
(102 pages)
Temperature Controller Omega CN8200 Series User Manual
1/16 din temperature & process controllers (29 pages)
Temperature Controller Omega i Series User Manual
Temperature & process monitor, temperature & process limit alarm (57 pages)
Temperature Controller Omega CN9000A Series User Manual
(92 pages)
Temperature Controller Omega CYD211 User Manual
Single input temperature monitor (76 pages)
Temperature Controller Omega CN4000 Series User Manual
(13 pages)
Temperature Controller Omega CND3 Series User Manual
(28 pages)
Temperature Controller Omega OS136A Series User Manual
Miniature low-cost non-contact infrared temperature sensor/transmitter (16 pages)
Temperature Controller Omega OS130A Series User Manual
Non-contact infrared temperature sensor/transmitter (16 pages)
Related Content for Omega CN63100 Series
CYD211 Curve Header Parameters
Omega CYD211
i Series Figure 2.10 Communication Output Wiring Hookup A) Rs-232 Output
Omega i Series
CN9000A Series Second Output Operation
Omega CN9000A Series
CN8200 Series Output Types
Omega CN8200 Series
FUZZY LOGIC CN4800 Cn4800 Wiring Diagram [When The Output 1 Is Relay (Spst) Output, Ssr Drive Output Or Current Output]
Omega FUZZY LOGIC CN4800
CNi8 Figure 2.11 Communication Output: A) Rs-232 Output - Wiring Hook Up
Omega CNi8
CN1001-RTD Analog And Relay Output Connections
Omega CN1001-RTD
C9000A SERIES Second Output Operation