  • Page 1 User’s Gui d e Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info NORWALK, CT CN4000 SERIES Temperature Controllers...
  • Page 2 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
  • Page 3: Table Of Contents

    CONTENTS MODEL CONFIGURATION…….………………………………………….…………….2 SPECIFICATIONS………………………………………………………………….……..3 PARAMETER AND SETTING……………………………………………………………4 SYMBOL DESCRIPTIONS…………………………………………..…………………..7 INSTRUMENT INSTALLATION AND WIRING……..………………………….………8 DISPLAY AND OPERATIONS…………………………………………...……….……..9 OPERATION DESCRIPTION……………….…………………..……………….….…10 MODEL CONFIGURATION Model Description CN4116 (*)-(**)-(***) 1/16 DIN controller CN4216 (*)-(**)-(***) 1/16 DIN controller, with 0.0 decimal CN414 (*)-(**)-(***) 1/4 DIN controller CN424 (*)-(**)-(***) 1/4 DIN controller, with 0.0 decimal CN418V (*)-(**)-(***)
  • Page 4: Specifications

    SPECIFICATIONS Thermocouple Input Type PT100 0 to1300 ℃ 0 to1700℃ 0 to1600℃ 0 to1000℃ 0 to1200℃ 0 to 1300℃ -200 to 800℃ Range ℃/ ℉ 32 to 2372 ℉ 32 to 3092 ℉ 32 to 2412 ℉ 32 to 1832 ℉ 32 to 2192 ℉...
  • Page 5: Parameter And Setting

    PARAMETER AND SETTING Field parameter table (Primary parameters) Code Description Remarks Setting Range Default Alarm on when PV>HIAL High limit alarm -999~+3000 3000 HIAL alarm off when PV<HIAL- AHYS Alarm on when PV<LoAL; Low limit alarm -999~+3000 -999 LoAL alarm off when PV>LoAL + AHYS Deviation high Alarm on when PV-SV>HdAL;...
  • Page 6 System parameter table (Secondary parameters) Set the parameter ‘Loc’=808 to enter: Avoid frequent alarm on-off action because of the Alarm Hysteresis 0~200 AHYS fluctuation of PV Alarm LdAL HdAL LoAL HIAL Output to (x 1000) (x100) (x10) (x1) 1111 None Alarm output 0~1111 according...
  • Page 7 Parameter Scb is used to make input shift to compensate the error produced by sensor or input -199~ Input Shift signal itself. +400 PV-after-compensation= PV-before-compensation + Scb. The value of FILt will determine the ability of filtering noise. When a large value is set, the measurement input is stabilized but the response speed is slow.
  • Page 8: Symbol Descriptions

    SYMBOL DESCRIPTIONS Symbol Description Input specification setting is incorrect orAL Input wiring is disconnected/ thermocouple problem Short circuited HIAL High limit alarm LoAL Low limit alarm HdAL Deviation high alarm LdAL Deviation low alarm EErr IC Software error 8888 IC Software error...
  • Page 9: Instrument Installation And Wiring

    INSTRUMENT INSTALLATION AND WIRING Wiring graph for instruments with dimension 1/4 DIN; 1/8 DIN Vertical and Horizontal N o t e : T h e c o m pe ns a t i o n wires for different kinds of thermocouple are different, and should be directly connect to the terminals.
  • Page 10: Display And Operations

    DISPLAY AND OPERATIONS ① Upper display window, displays PV, parameter code, etc. ② Lower display window, displays SV, parameter value, or alarm ③ Setup key, for accessing parameter table and conforming parameter modification. ④ Data shift key, and auto tuning. ⑤...
  • Page 11: Operation Description

    OPERATION DESCRIPTION Set Value Setting: In basal display status, if the parameter lock “Loc” isn't locked, we can set 、 setpoint (SV) by pressing . Press key to decrease the value, key to increase the value, and key to move to the digit expected to modify.
  • Page 12 Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
  • Page 13 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers &...