Omega OS136A Series User Manual

Omega OS136A Series User Manual

Miniature low-cost non-contact infrared temperature sensor/transmitter
Hide thumbs Also See for OS136A Series:

Advertisement

Quick Links

TM
CAUTION! - This product
!
is not intended for medical
use or use on humans
CAUTION! - This product
!
is not intended for medical
use or use on humans
Temperature Sensor/Transmitter
OS136A SERIES
Miniature Low-Cost
Non-Contact Infrared
User's Guide
Shop online at
omega.com
e-mail: info@omega.com
For latest product manuals:
www.omegamanual.info
NORWALK, CT

Advertisement

Table of Contents
loading

Summary of Contents for Omega OS136A Series

  • Page 1 CAUTION! - This product is not intended for medical use or use on humans Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info NORWALK, CT OS136A SERIES Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter...
  • Page 2 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
  • Page 3: Table Of Contents

    OS136A Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter Table of Contents Section Page Caution and Safety Information ..............iii Safety Warnings and IEC Symbols ............. iii Section 1 Introduction ..................1 Section 2 Installation ..................1 2.1 Unpacking .................. 1 2.2 Electrical Connection ..............
  • Page 4 OS136A Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter List of Figures Figure Description Page General Wiring Diagram ............... 2 Optical Field of View ..............3 Mounting Bracket, OS100-MB ............4 Air Purge Collar, OS100-AP ............4 Stainless Steel Housing ..............5 Water/Air Cool Jacket, OS136-WC ..........
  • Page 5: Caution And Safety Information

    OS136A Series Miniature Low-Cost Non-Contact Infrared Temperature Sensor/Transmitter CAUTION & SAFETY INFORMATION If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impaired. The Installation category is one (1).
  • Page 6: Section 1 Introduction

    The model OS136A series is a very low-cost, super-compact infrared transmitter. It measures temperature via non-contact, and provides an analog output proportional to the measured temperature. The OS136A series is offered in two temperature ranges: -18 to 204ºC (0 to 400ºF) and 149 to 538ºC (300 to 1000ºF).
  • Page 7: Electrical Connection

    Installation The following describes the ordering information: OS136A – * – ** , where - * means: -1 : -18 to 204ºC (0 to 400ºF) Temperature range -2 : 149 to 538ºC (300 to 1000ºF) Temperature range - ** means: -MA : 4 to 20 mA current output -V1 : 0 to 5 Vdc output -V2 : 0 to 10 Vdc output...
  • Page 8: Section 3 Operation

    Operation SECTION 3 – OPERATION 3.1 – Measuring Temperature Before starting to measure temperature, make sure the following check list is met: The Power and output connections are made (Fig 2-1) The target is larger than the optical field of view of the transmitter (Fig 3-1) Use the Laser Sighting accessory (Optional), to align the transmitter to the center of the target area.
  • Page 9: Atmospheric Quality

    Operation 3.3 - Atmospheric Quality Environments with smoke , dust, and fume dirty up the optical lens, and cause erroneous temperature readings. To keep the surface of the optical lens clean, the air purge collar accessory is recommended, OS136-AP (Fig 3-3). The following figures show the Mounting Bracket (OS136-MB), Air Purge Collar (OS136-AP), Stainless Steel Housing, Water/Air Cool Jacket (OS136-WC), and the Water/Air Cool Jacket Assembly.
  • Page 10: Stainless Steel Housing

    Operation 3/4-16 UNF LIGHT HEX KNURL 4.76 (3/16) WIDE 33.27 (1.31) 88.9 (3.5) 1.83m (6ft) DIMENSIONS mm (in) Figure 3-4. Stainless Steel Housing 1/8 NPT COMPRESSION 7.62 FITTING, 2 PLCS. (0.30) INLET OUTLET 85.09 (3.35) 3/4-16 UNF-2B 3/4-16 UNF Dimensions mm (in.) Figure 3-5.
  • Page 11: Section 4 Laser Sight Accessory

    Laser Sight Accessory SECTION 4 - LASER SIGHT ACCESSORY 4.1 – Warning and Caution CAUTION: You may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED HERE MAY RESULT IN HAZARDOUS RADIATION EXPOSURE.
  • Page 12: Laser Sighting Accessory, Os100-Ls

    Laser Sight Accessory LASER WARNING LABEL DC POWER JACK OS136A LED LASER POWER LASER INDICATOR BEAM (0.75) ON/OFF 50.8 SWITCH (2.0) POWER CABLE BATTERY PACK Dimensions mm (in.) POWER SUPPLY Figure 4-1. Laser Sighting Accessory, OS100-LS Figure 4-2. Laser Warning Label...
  • Page 13: Section 5 Specifications

    Specifications SECTION 5 – SPECIFICATIONS 5.1 - General Temperature Range OS136A-1: -18 to 204ºC (0 to 400ºF) OS136A-2: 149 to 538ºC (300 to 1000ºF) Accuracy: OS136A-1: 3% of Rdg or 4.4ºC (8ºF) whichever is greater OS136A-2: 3% of Rdg or 5.5ºC (10ºF) whichever is greater From 185 to 510ºC (365 to 950ºF) Repeatability: 1% of Rdg.
  • Page 14: Laser Sight Accessory

    Specifications 5.2 - Laser Sight Accessory Laser Wavelength (Color): 630 - 670 nm (Red) Operating Distance: Up to 9.1 m (30 ft.) Max. Laser Power Output: Less than 1 mW @ 22ºC ambient European Classification: Class 2, EN60825-1/11.2001 FDA Classification: Class II Laser Product.
  • Page 15 Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
  • Page 16 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers &...

This manual is also suitable for:

Os136a-1Os136a-2

Table of Contents