The following document outlines the troubleshooting steps to determine why an MCB is not powering up (or there are no
diagnostic LED turned on). The main symptom is that the display or embedded touch screen will not turn on.
The procedures in this troubleshooting document require the power to be on and the drive motor shroud to be
removed. Take extreme caution when working around live electronic components. If you are not comfortable
Some assumptions have been made as well:
The power cord is securely plugged into a wall outlet.
•
The outlet is supplying the appropriate amount of AC voltage.
•
The other end of the power cord is secured in the unit.
•
The power switch is set 'on' and/or the breaker on the treadmill has not been tripped.
•
Do not continue with the rest of the document until these have been confirmed.
The following tools will be needed:
Phillips screwdriver
•
Multi-meter
•
Verify Power Coming from EMI Filter
1. Turn the power switch to the off position.
2. Locate the EMI Filter (Fig. 1) and disconnect the two wires that go to the MCB (Fig. 2).
Fig. 1
STAR TRAC FITNESS
MCB Will Not Power Up
AC MCB's
working around electricity, do no perform this procedure.
1 of 4
Troubleshooting
Fig. 2
637-1378 Rev: A