Replacing The Heat Sink - Fujitsu PRIMERGY TX200 S5 Options Manual

Hide thumbs Also See for PRIMERGY TX200 S5:
Table of Contents

Advertisement

Processors
6.3

Replacing the heat sink

Ê Open the server and remove system fan 2 (or 2&4) as described in the
chapter
"Preparation".
Ê Press the heat sink retaining clips downward and inward to release them.
Ê Swing the heat sink retaining clips up as far as they will go.
Ê Loosen the heat sink by turning it back and forth and then lift it out.
Ê Clean the upper side of the processor using a lint-free cloth.
Ê Remove the protective cover from the new heat sink.
Ê Mount the heat sink on the processor so that the side with the visible copper
heat pipes is pointing in the direction of the memory slots.
Ê Fold down the two heat sink retaining clips at the same time and lock the
heat sink by returning the heat sink retaining clips to their original position.
Ê Reinstall system fan 2 (or 2&4) as described in the
Ê Close the server, connect it to the power outlet, and switch it on as described
in the
chapter
TX200 S5
"Completion".
Options Guide
Replacing the heat sink
chapter
"Completion".
43

Advertisement

Table of Contents
loading

Table of Contents