Ê Install the redundant system fan 1&3 and connect both fan cables to the
system board as described in the
on page
93.
I
The redundant system fan 1&3 (dual fan, two fans are integrated
internally) is taller and has two fan cables.
Ê Install the redundant system fan 2&4 and connect both fan cables to the
system board as described in the
on page
94.
I
The redundant system fan 2&4 (dual fan, two fans are integrated
internally) has two fan cables.
V
CAUTION!
For safety reasons (danger of tipping) an anti-tilt bracket must be
mounted on the rear side of floorstand models with hot-plug power
supply.
Ê Place the server on the anti-tilt bracket. and fasten the anti-tilt bracket
using the two knurled screws (see
Ê Close the server, connect it to the power outlet, and switch it on as described
in the
chapter
86
Conversion to hot-plug PS and redundant system fans
"Completion".
Options Guide
section "Installing system fan 1 (or 1&3)"
section "Installing system fan 2 (or 2&4)"
figure 78 on page
87).
TX200 S5