When Alarm is set to
is disabled, however the alarm will still sound for low power,
high heat, or low disk space conditions.
Stop Frame, Gray, No Video
•
STOP FRAME
Displays the first frame of the clip.
•
STOP GRAY
Displays a black frame.
•
STOP NO VIDEO
Video output is
EXT CTL OFF, Pause, Frame, File
These options permit the use of an external device to control the FS-4
through the optional RS-232 cable.
RS-232 Cable Available from Focus Online Store
The RS-232 cable required to connect the FS-4 to an external control device
is Focus part number CBLA-0114-01. It and other accessories mentioned in
this manual are available at https://www.focusinfo.com/sales/store.
•
EXT CTL OFF
Use this option when connecting an external device with an
RS232C cable.
•
This requires the use of a a 3.5mm-to-DB9 adapter cable,
plugged into FS-4
In Local mode, select this item to control the FS-4 with the
optional wired remote control unit, refer to page 83.
The following options permit control functions to occur from a
simple contact closure.
•
EXT CTL PAUSE
Controls
session.
•
EXT CTL FRAME
Captures a single frame of video and records it to a file. Each
time this function is triggered, it sequentially adds another
frame to the same file until stopped.
•
EXT CTL FILE
Creates a new file during a record session without losing any
frames.
Off
Group Default
.
Off
Control
and
Pause
Resume
DV Mode Only
, the audio feedback for the buttons
port.
during a record or playback
FireStore Functions