Network Reports; Program Mode 99 - QUORION QMP 3000 User Manual

Electronic cash register
Table of Contents

Advertisement

Example 2:
External EPSON TM-88 printer of REGISTER# 1 port# 2 as a network KP1 printer.
PARAMETER 21 value 3 which means EPSON TM-88
PARAMETER 22 as 12 which means register#1 and port# 2.
Note that you must program these values in all registers which use this printer.
Note: When using a slip printer as shared network printer the register checks the paper
when the transaction is closed. This means that it will always print on the slip when the
option print on slip is activated even when compulsory slip is not set.

7.5.6 Network Reports

It is possible to set OPTION 1-8 in a USER REPORT which will automatically make this
report a NETWORK report. Note that also the NETWORK SIZE (PARAMETER 55) must
be programmed. Whenever a USER report is taken with this option set the register will
check if all registers are online and take a consolidated report. When not all register are
online the register will give an error an not take the report. You must first switch on the
register or disable it with program mode 99.
It is also possible to take a USER REPORT as network report without setting OPTION 1-8.
When you add 1000 to the report number the register will also take the USER report as a
network report.
It is also possible to take a SYSTEM REPORT as network report When you add 10000000
to the system report code the register will also take the SYSTEM REPORT as a network
report.

7.5.7 Program Mode 99

With program mode 99 it is possible to disable or enable a register in the network. In order
to avoid the loss of data the registers in the network will try to sent print, balance and
article data for ever when an error occurs until you disable the register using MODE 99.
When you enable or disable a register in the network using mode 99 the register will
transmit the information to all active registers in the network when NETWORK SIZE is set
else it will only disable the register. You enter the mode by entering 99 on the TYPE key
and the register will show the status of the registers in the network. When network size is
not set the status of 24 (maximum) registers will be shown. By pressing the ENTER (CR)
key you can toggle the status of the register.
Note: When you are enabling a register take care that is enabled in all connected registers
because the register will not transmit the information to registers which are disabled.