7.10. Power Up Options (Page 11)
Two power up options are provided as follows:
Logo On/Off– This refers to the logo animation
displayed a start up.
Output Level Ramp – This is used to apply a gradual ramp up to full output levels when you
power on the unit, for example, to avoid sudden power surges in larger systems. The ramp
can be adjusted between 0 – 32s and will recover the output mute states held when the unit
was last switched off. Alternatively, an initial mute can be automatically applied to all of the
outputs (on a ramp setting; this is the default setting.
To switch the logo on/off, turn the left DATA ENTRY control knob
To change the ramp up time at the outputs, turn the centre DATA ENTRY control knob.
The 'Outputs Muted' option is found just below 0s.

7.11. Ethernet Settings (Pages 12 and 13)

When controlling the DN9848E unit remotely via Ethernet, the unit requires an individual IP Address
and Subnet Mask to be set. For more information on DN9848E remote control set ups, see Section 9.
7.11.1
Ethernet IP Address (Page 12)
The IP Address is entered manually on each unit in the network using the DN9848E's front panel
controls.
To check the current IP Address
1
With the DN9848E connected to
your network, step through the
Set Up menus to the Ethernet IP
Network setup page shown
opposite.
2
Turn the left DATA ENTRY control
knob and the unit will scan the
network to obtain the IP address.
At the end of the scan, which takes a few seconds, the display updates with an IP address as shown
above. The Default IP Address is 192.168.1.1.
To set the IP Address
1
Turn the left DATA ENTRY control knob to highlight the area of the IP Address you wish to
change.
2
Now turn the centre control knob to select a number from 0 to 255.
3
Press the HOME button to confirm the new IP Address.
It is important that all units and the controlling PC have a unique IP
Note
Address in order for the network to function correctly. For more
information on configuring your network, please see the HELIX DN9848E
RCS User Guide.