3. R
P
EAR
ANEL
1
2
1
IEC fused mains
inlet socket
2
Ethernet
3
Outputs 1-8
4
Inputs A-D
Controls, Connectors, Indicators
3
For mains power connection. Accepts input voltages from
100-240V AC 50/60Hz.
2-port Ethernet switch for remote control using Cat-5
cabling.
Electronically balanced XLR audio output plugs
Pinouts:
Pin 1 - Screen
Pin 2 - Hot
Pin 3 - Cold (Return)
Analogue – electronically balanced XLR audio input sockets
Pinouts:
Pin 1 - Screen
Pin 2 - Hot
Pin 3 - Cold (Return)
Digital – inputs A and C support incoming 96kHz AES/EBU
signals. Note that when digital input is selected, inputs B
and D are inactive.
AES/EBU is 110 Ohms. Sample rate converters (SRCs)
support incoming signals at sampling frequencies from
32kHz to 96kHz ±12.5%, while allowing the unit to operate
internally at 48kHz. An SRC bypass facility is available for
48kHz operation; this is to eliminate the propagation delay
through the SRC.
Pinouts:
Pin 1 - Screen
Pin 2 - Data +
Pin 3 - Data -