Action
Entry delay
Exit delay
Protest beep
Trouble beep
Keypress
Police Alarm
Emergency Alarm Programmed Level
Fire Alarm
22

Siren

The siren is capable of low and high sounds. Low level sounds for non-alarm cases such as key-
presses and trouble beeps. High level sounds are used for alarm situations.
Table B7: Volume Level and Pattern
Volume Level
Programmed Level
One beep every 4 seconds, last 10 seconds 1 beep every second.
If Alarmed: Three beeps every 10 seconds, last 10 seconds 3 beeps every second.
Programmed Level
One beep every 4 seconds, last 10 seconds 1 beep every second.
Programmed Level
Long beep followed by short beep.
Programmed Level
4 beeps per minute.
Low
1 beep.
High
Constant.
On/off pattern.
High
Temporal three - .5 s on, .5 s off, .5 s on, .5 s off, .5 s on, 1.5 s off.

Trouble Beeps

Trouble beeps will be silenced for 10 hours if the Status button is pressed or until one hour prior
to Quiet Hour for non-fire related troubles. Trouble beeps will be silenced for 4 hours if the Sta-
tus button is pressed and is not affected by Quiet Hour for fire related troubles.
Quiet Hour determines the start time of a 10 hour window during which trouble beeps are sup-
pressed. For example, if Quiet Hour is set to 10 p.m. trouble beeps will not occur between 10
p.m. and 8 a.m.
Beeps in Level 1 or 2 for the following conditions:
Low CPU Battery
Sensor Supervisories or Troubles
Sensor Low Battery
RF Jam
RF Trouble
Phone Module Failure
System Memory Failure
Pattern