Advertisement

Extension
function
code
This function is used to select a method to enter the target value for executing each PID function.
Setting method
Target
value
setting
method
selection
NOTE 1:
NOTE 2:
This function is used to set a target value level of PID controlling within 0 to 200%.
This function is valid when 0 is set for
Setting method
Internal
target
value level
setting
Select whether to start auto tuning as well as a mode. When 1 or 2 is set, auto tuning is started
during the first operation.
Auto
tuning
setting
(For details of auto tuning, see Appendix 1.)
Select the motor constant used for sensorless vectror control (SLV).
Motor
data
selection
2
1
FUNC
FUNC
Initial value
Set "1" when a PID optional board (J-PI) is used.
The value entered to the OS terminal of J-PI is assumed as the target value.
The target value at set "1" is O-L, OI-L input signal,
setting.
2
1
FUNC
FUNC
Initial value
Initial value
FUNC
2
1
2
1
FUNC
FUNC
Initial value
Contents and display
Set value
0
1
.
If an analog voltage is entered as a feedback
value, the feedback voltage (0 to 10V)
corresponds to this target value level
setting (0 to 200%). In other words, if,
when 5V is entered as the target feedback
value of a sensor, it is converted to an
internal target value, set 100% as this
internal target value.
Set value
0
Auto tuning is not performed.
1
Normal measurement mode
(The motor runs.)
2
R1, R2, or L measurement mode
(The motor does not run.)
Set value
0
1
2
7-27
Performance
The target value depends
on the
level set value.
The target value is set using
the
frequency setting
method.
setting or multispeed
Function
Data used
Old Hitachi general-
purpose motor data
New Hitachi general
purpose motor data
(ÒThe MotorÓ)
Auto tuning data
Initial
value
Initial
value