Hitachi J300U Series Instruction Manual page 105

Three phase input 200/400v class
Hide thumbs Also See for J300U Series:
Table of Contents

Advertisement

(Function mode 1)
Display
Function
Function
sequence
No.
name
34
F-41
Position
Electronic setting
gear
switching
setting
Numerator
of ratio
Denominator
Feed for-
ward gain
Position
loop gain
35
F-42
Torque
Torque
limit
limit
setting
setting
switching
(Note 1)
Plus torque
limit
Minus
torque limit
36
F-43
PID target
PID control value input
setting
method
switching
selection
PID target
value setting
P gain setting
I gain setting
D gain setting
Selection
37
F-46
Transmission
Communi- speed
cation
selection
protocol
Station
setting
number
selection
Transfer bit
length
selection
Parity
ON / OFF
selection
Parity
even / odd
selection
Stop bit
length
selection
NOTE 1: Smaller levels of torque limit and overload restriction are given top priority and valid for any control
method.
(Function mode 2)
Initialization display
contents
PO EGRP
FB
PO EGR-N
00001
PO EGR-D
00001
PO FFWG
000.00
PO G
000.50 rad/s
TRQ LIMIT
REM
TRQ FWD
150%
TRQ REV
150%
PID IN-SEL
IN
PID LVL
000.00%
PID P
1.0
PID I
01.0S
PID D
000.0
PID MODE
MD0
COM BAU 00600 bps
COM NUMBER
01
COM LENGTH
8
COM PAR-SEL1
ON
COM PAR-SEL2 EVN
COM STOPBIT
2
12-14
Setting, change
Initialization
contents
FB
FB/REF
1
1 to 9999
1
1 to 9999
0
0 to 655.35
0.5
0 to 100
rad/s
REM
REM/OP1/OP2
150%
20 to 150%
150%
20 to 150%
IN
IN/OUT
0%
0 to 200%
1.0
0.1 to 5.0
1.0
0 to 15.0
000.0
0 to 100
MD0
MD0 to 4
600
300/600/1200/
2400/4800/9600/
19200
1
1 to 32
8
8/7
ON
ON/OFF
EVN
EVN/ODD
2
2/1
Setting contents
Effective with option board
(J-FB)
REM: Each operator
PO1: Option 1
PO2: Option 2
Regenerative mode
Effective with option board