Hitachi J300U Series Instruction Manual page 101

Three phase input 200/400v class
Hide thumbs Also See for J300U Series:
Table of Contents

Advertisement

(Function mode 1)
Display
Function
Function
sequence
No.
name
19
F-26
Frequency
Frequency lower limiter
limiter
setting
Frequency
upper
limiter
setting
20
F-27
Jump
Jump
frequency
frequency setting (1)
Jump
frequency
setting (2)
Jump
frequency
setting (3)
Jump
frequency
width setting
21
F-28
STOP key
validity
selection
during
terminal
running
22
F-29
Running
direction
selection
Reverse run F/R PREV
prevention
selection
Reduced
voltage
soft start
setting
23
F-30
Maximum
frequency
selection
24
F-31
Analog input IN ANA
External
voltage
analog
selection
frequency External
command frequency
start setting
External
frequency
end setting
External
frequency
start setting
rate
External fre- IN EX%E
quency end
setting rate
External
command
start point
selection
(Function mode 2)
Initialization display
contents
LIMIT L
0000.0 Hz
LIMIT H
0000.0 Hz
JUMP F1
0000.0 Hz
JUMP F2
0000.0 Hz
JUMP F3
0000.0 Hz
JUMP W
0.5 Hz
STOP-SW
ON
F/R SW
FRE
OFF
F/R RVS
6
F-MAX-L
120 Hz
10 V
IN EXS
0000.0 Hz
IN EXE
0000.0 Hz
IN EX%S
000%
100%
IN LEVEL
0 Hz
12-10
Setting, change
Initialization
contents
0 Hz
0 to 120.0
(400) Hz
0 Hz
0 to 120.0
(400) Hz
0 Hz
0 to 400 Hz
0 Hz
0 to 400 Hz
0 Hz
0 to 400 Hz
0.5 Hz
0 to 9.9 Hz
ON
ON: STOP key
valid
OFF: STOP key
invalid
FRE
FWD/REV/
FRE
OFF
ON/OFF
6
0 to 6
120 Hz
120/400 Hz
10 V
10/5
0 Hz
0 to 120.0 (400)
0 Hz
0 to 120.0 (400)
0%
0 to 100
100%
0 to 100
0 Hz
0 Hz/ExS
Setting contents
The lower limit of the frequency
to be set is set. When the lower
limit is 0, the setting is invalid.
The upper limit of the frequency
to be set is set. When the upper
limit is 0, the setting is invalid.
• The section where frequencies
are to be jumped is set.
• Up to three locations can be
set.
• When the number of locations
is 0, the setting is invalid.
• The frequency width where
frequencies are jumped is set.
Whether or not to make the
STOP key valid during terminal
running is selected. In the
Remote mode, the STOP key is
always valid.
FWD: Only forward run
REV: Only reverse run
FRE: Both forward run and
reverse run valid
Reverse run prevention
ON:
OFF:
Maximum frequency switching:
120: 120 Hz 400: 400 Hz
Input voltage maximum level
10: Max. 10 V 5: Max. 5 V
• Frequency at which the
external input starts
• Frequency at which the
external input is maximized
• Input start level
• Input maximum level
EXS: Start at EX%S setting
rate or less