Hitachi J300U Series Instruction Manual page 97

Three phase input 200/400v class
Hide thumbs Also See for J300U Series:
Table of Contents

Advertisement

(Function mode 1)
Display
Function
Function
sequence
No.
name
6
F-05
Motor
Motor
M setting
constant
constant
Motor
J setting
constant
Motor
constant
Kp setting
Motor
constant
Ti setting
Motor
constant
KPP setting
7
F-06
Accelera-
Accelera- tion time
tion time
setting
2-stage
acceleration
time setting
Curve
pattern
selection
for
acceleration
Accelera-
tion and
deceleration
curve
constant
selection
8
F-07
Decelera-
Decelera- tion time
tion time
setting
2-stage
deceleration
time setting
Curve
pattern
selection
for
deceleration
Accelera-
tion and
deceleration
curve
constant
selection
(Function mode 2)
Initialization display
contents
AUX M
123.60 mH
2
AUX J
0.44 kgm
AUX Kp
002.00
AUX Ti
00100 ms
AUX KPP
001.00
ACC 1
0030.00 s
ACC 2
0015.00 s
ACC LINE
L
ACC GAIN
02
DEC 1
0030.00 s
DEC 2
0015.00 s
DEC LINE
L
DEC GAIN
02
12-6
Setting, change
Initialization
contents
Rated capacity
0 to 655.35
of each inverter
Rated capacity
0 to 655.35
of each inverter
2.0
0 to 100.00
100 ms
0 to 10000
1.0
0 to 100.00
30.00 s
0.01 to 3000
15.00 s
0.01 to 3000
L
L (Linear),
S (S curve),
U (U curve),
RU (reverse
U curve)
2 (common to
1 to 10
acceleration
and
deceleration)
30.00 s
0.01 to 3000S
15.00 s
0.01 to 3000S
L
L (Linear),
S (S curve),
U (U curve),
RU (reverse
U curve)
2 (common to
1 to 10
acceleration
and decelera-
tion)
Setting contents
• Primary self inductance per
phase.
• Motor and machine inertia
• Smaller: High response
• Larger: Low response
• Set this item after the
feedback option PCB is
installed.
• Set this item after the
feedback option PCB is
installed.
• When the fuzzy most
suitable acceleration and
deceleration (F-10) are set,
the time displayed here is
invalid, though it can be
set.
• The acceleration time can
be used when the input
terminal CH1 is shorted.
• For input terminal
selection, refer to F-34
input terminal.
• The curve pattern is set for
acceleration and
deceleration respectively.
• When the constant is set
for one of acceleration and
deceleration, it is common
to both acceleration and
deceleration.
• See appendix 4.
• When the fuzzy most
suitable acceleration and
deceleration (F-10) are set,
the time displayed here is
invalid, though it can be
set.
• The deceleration time can
be used when the input
terminal CH1 is shorted.
• For input terminal
selection, refer to F-34
input terminal.
• The curve pattern is set for
acceleration and decelera-
tion respectively.
• When the constant is set
for one of acceleration and
deceleration, it is common
to both acceleration and
deceleration.
• See appendix 4.