Hitachi J300U Series Instruction Manual page 115

Three phase input 200/400v class
Hide thumbs Also See for J300U Series:
Table of Contents

Advertisement

(3) New remote operator
First hierarchy
1 Command
2 Initial
3 Function
4 Option
Second hierarchy
1
Control
2 Acc/Dec
3 Run
4 Braking
Third hierarchy
1 V/f
2 Motor
3 Carrier
Fourth hierarchy
1 AUTO
2 DATA
1 AUTO
2 DATA
Monitor display
FS
50.00Hz
0.00Hz
AC1
10.00s
DC1
10.00s
0:NOR
(0-2)
0:NOR
(0-2)
1:AUT
(0-2)
0:NOR
(0-2)
Select "3 Function" in the first hierarchy.
2
SEL
Select "1 Control" in the second hierarchy.
SEL
Select "2 Motor" in the third hierarchy.
SEL
Change the content of "1 Auto" from
0:NOR to 1:AUT in the fourth hierarchy.
When the data is changed, press the
1
key.
STOR
When the
the monitor mode and the equipment starts
running, the autotuning is executed.
MON
A-3
MON
key is pressed to select
STOR

Advertisement

Table of Contents
loading

This manual is also suitable for:

J300 series

Table of Contents