4630 and 4830 Bar Code Label Printers User's Manual
Error Message
RIBBON FAULT
SELF-STRIP
NOT CONNECTED
SENDER ERROR
STATE FAULT
STRUCT FAULT
SYNTAX ERROR 24
SYNTAX ERROR 33
SYNTAX ERROR 34
SYNTAX ERROR 35
SYNTAX ERROR 44
SYNTAX ERROR 46
SYNTAX ERROR 54
TRACE FAULT
TYPE FAULT
4-10
Problem
You are out of thermal transfer ribbon
or it is jammed.
The self-strip assembly is not
connected.
If you are using the Cloning or
Selective Transfer commands, the
Sender printer is not set up properly to
send information to the Receiver.
The printer microprocessor has
detected an internal fault.
The printer microprocessor has
detected an internal fault.
Missing preamble or postamble data.
Invalid field delimiter. Either a start or
end character is missing or they are
different types.
Invalid <ESC> command.
Invalid <SI> command.
Semicolon (;) missing after <ESC>P.
Statement does not make sense.
Invalid UDC command.
The printer microprocessor has
detected an internal fault.
The printer microprocessor has
detected an internal fault.
Solution
Clear the jam or replenish the ribbon
stock. Press Feed/Reload to clear the
alert.
Make sure the self-strip assembly is
connected properly, or disable this
option. Press Feed/Reload to clear the
alert.
Check all connections between the
Sender and the Receiver printers.
Make sure the Sender printer is set up
correctly for transmitting information
to the Receiver.
Contact your Intermec representative.
Contact your Intermec representative.
Delete the setup for preamble or
postamble data, or include the data.
Press Cont to clear the alert.
Check for all pairs of field delimiters
and make sure both are numeric, or
both are alphanumeric. Press Cont to
clear the alert.
Correct the command syntax. Press
Cont to clear the alert.
Correct the command syntax. Press
Cont to clear the alert.
If data follows <ESC>P you must
insert a semicolon (;) to separate
commands. Press Cont to clear the
alert.
Check the statement syntax. Press Cont
to clear the alert.
Correct the UDC command syntax.
Press Cont to clear the alert.
Contact your Intermec representative.
Contact your Intermec representative.