3-18. INFORMATION MODE
(Continued)
3-39
Press
to view the specific status of each input. An
underscore ("_") indicates the input is not presently detected.
A checkmark (" ") indicates the signal is detecting a normal
input. A blinking ("X") indicates the signal is presently
detected, but is detected as a half-wave (partially failed) input.
The V, H, D, S, F, P and M signals below are wired in
series. The first signal missing out of this sequence
generally causes all signals to the right of it to be
missing as well.
Press
to continue onto OUTP H* P_.
6. OUTP H* P_
This mode displays the status of components and outputs. If
the output signal is detected, an identifying letter is displayed
(see below), followed by an "*". If the output is off, "_" is
displayed.
"H" = Heat output
"P" = Pressure output (pressure fryers only)
If heat is on, "H*" shows in display. If heat is off, "H_"
shows in display. If controls senses a problem with the heat
output, "H*" shows in display, with the "*" flashing.
If pressure is on, "P*" shows in display. If pressure is off,
"P_" shows in display. If controls senses a problem with the
pressure output, "P*" shows in display, with the "*" flashing.
Press
to view the amp "DRAW" status of each output.
"H " and "P " in the display means the amps are good. A
flashing "X" behind the H or P means too much current.
Press
to view the No Connect/Ground ("NC/GND")
status of each output. This monitors a possible problem with
the relays on the output PC board.
"H
" and "P " in the display means everything on the output
PC board is good. A flashing "X" behind the H or P means a
problem exists.
Press
to view the outputs and inputs (see step 10) together.