Henny Penny OFE- 291 Operation page 29

Section 3. operation
Hide thumbs Also See for OFE- 291:
Table of Contents

Advertisement

3-16. SPECIAL PROGRAM
MODE (Continued)
3-29
Type of shortening to be melted - Liquid or Solid (SP-6)
The Melt Cycle can be set to the type of shortening being used.
a. Follow steps 1 and 2 above.
b. Press and release
and "MELT CYCLE SELECT" flashes on the display,
along with "l=LIQ" or "2=SOLID".
c. Press
to toggle from one type to another.
The type of shortening being used in the fryer
determines the amount of heat applied during the
Melt Cycle. If the controls are set to the solid
setting, less heat is applied to the shortening, than if
the controls were set to liquid. Too much heat
applied to solid shortening causes much smoking,
and could cause a fire. Match this setting to the type
of shortening being used at the time.
When using new shortening, it is recommended to melt
the shortening on an outside source before placing
shortening in the frypot. Unless elements are
completely covered in shortening, fire or damage to the
frypot could result.
Idle Mode (SP-7)
A programmed Idle Mode allows the shortening temperature to
drop to a lower temperature when not in use. This saves on the
shortening and utilities.
a. Follow steps 1and 2 above.
b. Press and release
MODE ENABLED?" flashes in the display, along with
"NO" or "YES".
c. Press and release
or vice versa.
d. With "YES" in the display, the Idle Mode is enabled.
Press and release
"IDLE SETPT TEMP" shows in the display, along with
the preset temperature.
Model OFE- 291
5 times. "SP-6"
6 times. "SP-7" and "IDLE
to toggle from NO to YES,
. "SP-7A" and
403

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ofe-291

Table of Contents