NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer.
A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior
written approval of warranty repair or replacement.
Read and understand installation instructions before installing.
Verify CORRECT FUEL TYPE
Check carton model number.
Check fireplace label. Models ending in N are for natural gas; those ending in P are for propane (LP gas).
WARNING: Using the incorrect fuel can create a serious fire hazard and will void the warranties. Install in
accordance with local and/or national codes and ordinances. Follow the TEMCO installation instruc-
tions.
Supply service shutoff valve upstream of gas fireplace.
Gas line size adequate for input rating (BTU's per hour) of fireplace, per National Fuel Gas Code (NFPA54) in
the case of USA installations or Installation Code CAN 1-149 in the case of Canadian installations.
Make following checks:
Gas line integrity at supply line connection.
Glass front panel position.
Correct gas pressure. Inlet Pressure __________(inches w.c.) Manifold Pressure __________(inches w.c.)
Piezo ignitor function (millivolt control models only).
Pilot ignition.
Main burner ignition.
Proper flame pattern and color.
Positioning of logs (in accordance with instructions).
Clearances to combustibles (vent, framing, mantels, etc.).
Vent system in compliance with instructions. All joints and connections sealed.
Wall switch operation. Do not connect millivolt wiring, wall switch or valve to 120v line voltage unless units is
specifically DSI equipped.
Demonstrated proper operating procedure to homeowner.
Explained the need for proper cleaning and maintenance.
Check all fittings and connections for gas leaks, correct if necessary.
Please sign below that checklist has been completed and understood. DATE INSTALLED ____/____/____