PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING HEATERS
IMPORTANT: Read all instruc-
tions and warnings carefully
before starting installation. Fail-
ure to follow these instructions
may result in a possible fire haz-
ard and will void the warranty.
WARNING: If the information in
this manual is not followed ex-
actly, a fire or explosion may
result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or
any other appliance.
— What to Do If You Smell Gas
Do not try to light any appli-
ance.
Do not touch any electrical
switch; do not use any phone
in your building.
Immediately call your gas
supplier from a neighbor's
phone. Follow the gas
supplier's instructions.
If you cannot reach your gas
supplier, call the fire depart-
ment.
— Installation and service must be
performed by a qualified in-
staller, service agency or the
gas supplier.
This is an unvented gas-fired
heater. It uses air (oxygen) from
the room in which it is installed.
Provisions for adequate combus-
tion and ventilation air must be
provided. Refer to Page 4.
Models with "N" after the model number use natural gas;
models with "P" after the model number use Propane
(LP) gas.
INSTALLER: DO NOT DISCARD THIS MANUAL - Leave in fireplace for homeowner.
Vent-Free Gas Fireplaces
Models:
ADF3310N-4, ADF3310P-4
Homeowner's Installation and

Operating Instructions

This appliance is CSA Certified under ANSI Standard
Z21.11.2a-2001 as an unvented room heater
Temco Fireplace Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
Gas Fired
Unvented
Room Heaters
US
78623 11/03 Rev. 6

Advertisement

Table of Contents
loading

Summary of Contents for Temco ADF3310N-4

  • Page 1: Operating Instructions

    WARNING: If the information in Models: this manual is not followed ex- ADF3310N-4, ADF3310P-4 actly, a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or...
  • Page 2: Table Of Contents

    This book contains your operating and installation instructions and should be kept in a safe place. For you to realize all the advantages and use of the reliable service that has been engineered into your TEMCO fireplace, you must carefully follow all of the instructions contained in this book regarding installation and operation of the fireplace.
  • Page 3: Important Information

    1/2 psig (3.5 kpa). • WARNING: Failure to keep primary air opening(s) of the Models ADF3310N-4 and ADF3310P-4 may be installed in burner(s) clean may result in sooting and property sleeping quarters where permitted by local codes. DO NOT damage.
  • Page 4: Provision For Adequate Combustion And Ventilation Air

    Temco ADF3310 Series volume of these rooms to compute the total volume WARNING: This heater shall not be installed in a of the applicable space. confined space or unusually tight construction 2. Divide the space volume by 50 cubic feet to deter- unless provisions are provided for adequate mine the maximum BTU/Hr the space can support.
  • Page 5 Temco ADF3310 Series Ventilation Air from Outdoors for Unusually You may provide two permanent openings: one within Tight Construction 12" of the ceiling and one within 12" of the floor. Con- nect these items directly to the outdoors or spaces WARNING: If the area in which the heater may be open to the outdoors.
  • Page 6: Fireplace Dimensions

    Temco ADF3310 Series Fireplace Dimensions Rough Opening 21¹⁄₈" Depth 35³⁄₈" 1/2" 14¹⁄₂" Rough Opening Width 36" 1/2” Clearance to Combustibles not Required at This Point Rough Opening Height 1/2" Gas Connection 32¹⁄₈" Left Side Only 33¹⁄₂" 17" 31¹⁄₈" 3⁷⁄₈" 6⁷⁄₈"...
  • Page 7: Installation & Operating Instructions

    Temco ADF3310 Series Installation & Operating Instructions Framing Clearances Locating the Fireplace The fireplace may be placed directly on a combustible Figure 3 shows some of the many ways your fireplace floor, against a combustible wall at marked clearances may be installed. Consider the traffic pattern in your or on a raised wooden platform.
  • Page 8: Clearances

    Temco ADF3310 Series When the fireplace is installed over carpeting, vinyl tile Installation or any combustible material other than wood flooring, it must be installed on a metal or wood panel extending This list of specific instructions will help you make its full width and depth.
  • Page 9: Gas Connection

    Temco ADF3310 Series Pins Securing Top of WARNING: Connecting directly to an unregulated Screen Panel LP tank can cause an explosion. All piping must comply with local codes and ordinances or with the National Fuel Gas Code (ANSI Z223.1), whichever applies. Installation of a sediment trap is a requirement of this code.
  • Page 10: Gas Pressure Check

    Temco ADF3310 Series CAUTION: If the appliance’s operating pressures high pressures! Apply soapsuds (or a liquid deter- are not checked and adjusted, improper combus- gent) to each joint. Bubbles forming indicate a leak. tion may result in soot being produced.
  • Page 11: Gas Line Pipe Sizing

    Temco ADF3310 Series Gas Line Pipe Sizing NOTE: To determine the size of the branch gas line from the main gas line to the fireplace, enter the tables below (for iron pipe or copper tubing) using the distance from the gas meter or second stage regulator to the furthest appliance on the gas system.
  • Page 12: Finishing The Fireplace

    Temco ADF3310 Series Wallboard with Marble, Finishing the Fireplace Brick or Stone Facing Slate or Tile Facing There are a wide variety of finishing materials available Finished Wall Finished for your fireplace, from formal wall treatments with Brick or Wall...
  • Page 13: Lighting Instructions

    Clockwise Counterclockwise control knob counterclockwise to setting 2. 4. Refer to Figure 11. Locate the Fig. 11 10. The settings for models ADF3310N-4, ADF3310P-4 are: pilot. BTU/Hr (x 1000) 5. Refer to Figure 10. Push in the Setting Natural LP/Propane...
  • Page 14: Flame Check

    Temco ADF3310 Series Flame Check A periodic visual check of the flames should be made. The pilot flame should always be present when the appliance is in operation. (Fig. 14) In normal operation (at full rate for approximately 15 minutes) the following flame appearance should be...
  • Page 15: Maintenance

    Temco ADF3310 Series Maintenance Cleaning CAUTION: Before cleaning or moving logs or other parts of the unit, be sure to read the section on impor- tant safeguards. Cleaning should be done before the logs are used each year and after long periods of non-use. Professional...
  • Page 16: Servicing

    Temco ADF3310 Series Servicing Repair and replacement work should only be done by a Always shut off the gas supply and make sure the appliance qualified service technician. is cool before beginning any service operation. Always check for gas leaks after servicing.
  • Page 17: Warranty Information

    TEMCO, any component covered Pages 20 and 21 of this manual. under this warranty is found to be defective, TEMCO will, The limited warranty applies only to the original owner of at its option, repair or replace the defective component at...
  • Page 18: Installation And Startup Checklist

    INSTALLATION AND STARTUP CHECKLIST Customer Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement.
  • Page 19 INSTALLATION AND STARTUP CHECKLIST Installer’s Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement.
  • Page 20: Warranty Registration

    Mississauga, Ontario Canada L5T 2N6 Serial # ______________________________________ Model # ______________________________________ I certify that I have followed all codes and regulations and adhered to the TEMCO installation instructions. I have completed the proper installation and startup checklist. Installer’s Signature Print Installer’s Name...

This manual is also suitable for:

Adf3310p-4

Table of Contents