Regulator
Fitting
Fig. 40 White-Rodgers 25M18A-706PI gas control.
5. Check the air shutter opening for the corresponding
gas used. (Fig. 42)
6. With the main burner burning, read the pressure on
the manometer or pressure gauge. The pressure on
the gauge should read between 9.8" and 10.2" w.c.
7. Turn off the gas supply. Turn off the electrical
supply to the appliance.
8. Remove the manometer or pressure gauge. Tighten
the screw in the pressure tap.
9. Turn on the gas supply. Turn on the electrical
supply to the appliance.
10. Immediately test all gas line connections and the
control valve for gas leaks using a soap and water
solution or other gas detection solution. Bubbles
indicate a leak that MUST be corrected. Do not use
an open flame to test for gas leaks.
11. Using a ball point pen, fill out the conversion label
that is supplied with the conversion kit. Place the
conversion label adjacent to the rating plate.
Conversion Parts Included with Fireplace
Main Burner Orifice
Label, Conversion
77045
Temco DV1000/1200/1400DSN/DSP Series
DV1000DSP
DV1200DSP
T210
DV1400DSP
Fig. 41 Correct air shutter settings.
NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.
Table 1 Burner Orifice
Model
DV1000
DV1200
DV1400
DV1000
#56 - PCOAO70H21
#55 - PCOAO70H19
77697
Air Shutter Settings
Model
Opening A
3/32" (2.3mm)
3/16" (4.7mm)
1/4" (6.3mm)
Natural
Propane
Orifice
Orifice
#46
#45
#43
Model Number
DV1200
#54 - PCOAO70H08
77698
A
#56
#55
#54
DV1400
77699
29