Temco DV1000/1200/1400DSN/DSP Series
Model
DV1000DSN
DV1000DSP
DV1200DSN
DV1200DSP
DV1400DSN
DV1400DSP
Air Shutter Settings
Model
DV1000DSN
DV1000DSP
DV1200DSN
DV1200DSP
DV1400DSN
DV1400DSP
NOTE: These are minimum settings. Air shutter open-
ings may be increased to prevent flame sooting.
32
Direct Vent Units - Inputs - Orifice Size - Altitude
BTU/Hr
BTU/Hr
Min. Input
Max. Input
12,500
18,500
12,500
18,500
13,000
20,000
13,000
20,000
15,000
22,000
15,000
22,000
Opening A
Closed
3/32" (2.3mm)
Closed
3/16" (4.7mm)
1/8" (3.2mm)
1/4" (6.3mm)
Normal and High
Manifold Pressure
@ Max.
3.5"w.c.
10.0" w.c.
3.5" w.c.
10.0" w.c.
3.5" w.c.
10.0" w.c.
Fig. 43 Air shutter opening.
Orifice 0 - 2000ft. Altitude in USA
Orifice 0-4500ft Altitude in Canada
#46 DMS
#56 DMS
#45 DMS
#55 DMS
#43 DMS
#54 DMS
"A"