Temco DV1000DSN Homeowner's Installation And Operating Manual page 20

Dv1000/1200/1400dsn/dsp series direct vent zero clearance, gas fireplace heater
Table of Contents

Advertisement

Temco DV1000/1200/1400DSN/DSP Series
Simpson Dura-Vent Venting
Horizontal or Vertical Terminations
The Simpson Dura-Vent Direct Vent System (GS 4" x 6
5/8") offers a complete line of component parts for
installation of both horizontal and vertical installations.
Many items are offered in decorative black, as well as
galvanized finish. The galvanized finish may be used
for installation with your Temco gas fireplace.
The minimum components required for a basic horizon-
tal termination are:
1 Horizontal Termination Cap
1 Flue Adapter (45° Elbow)
1 Wall Penetration Heat Shield
1 Length of pipe to suit wall thickness (see chart)
Wall thickness is measured from the back of the
fireplace to the inside mounting surface of termination
cap. For siding (other than vinyl) furring strips may be
used, instead of the vinyl siding standoff, to create a
level surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used
with vinyl siding), measure to outside surface of wall
without siding and add 2" (51mm).
20
Flat Wall Installation (All Units)
Wall Thickness
inches (mm)
Required (inches(mm))
5 " - 7"
(140 - 178mm)
9 " - 11"
(241 - 279mm)
12 " - 14"
(318 - 356mm)
15 " - 17"
(394 - 432mm)
14 " - 19 "
11" - 14 " Adj. Pipe
(368 - 499mm)
20 " - 29"
(520 - 737mm)
Corner Installation (DV1000)
2 " - 4 "
(70 - 108mm)
5 " - 7 "
(146 - 184mm)
9 " - 11 "
(248 - 286mm)
12 " - 14 "
(324 - 362mm)
(152 + 305mm) (229 + 229mm)
13 " - 22 "
(349 - 565mm)
7 " - 12 "
11" - 14 " Adj. Pipe
(197 - 327mm)
Corner Installation (DV1200)
2
" - 3
"
(56 - 94mm)
5
" - 6
"
(132 - 170mm0
8
" - 9
"
(208 - 246mm)
9
" - 10
"
(233 - 272mm)
12
" - 13
"
(310 - 347mm) (152 + 229mm)/ (229 + 229mm)
13
" - 21
"
(335 - 551mm)
7
" - 12
"
11" - 14 " Adj. Pipe
(183 - 313mm)
Corner Installation (DV1400)
7 " - 8 "
(181 - 219mm)
10 " - 11 "
(257 - 295mm) (152 + 229mm)/ (229 + 229mm)
11 " - 19 "
(283 - 499mm)
5 " - 10 "
11" - 14 " Adj. Pipe
(130 - 260mm)
Vent Length
-
-
6"
(152mm)
9"
(229mm)
12"
(305mm)
(279 - 372mm)
17" - 24" Adj. Pipe
(432 - 610mm)
6"
(152mm)
9"
(229mm)
6" + 9"
(152mm + 229mm)
6" + 12" / 9" + 9"
17" - 24" Adj. Pipe
(432 - 610mm)
(279 - 372mm)
6"
(152mm)
9"
(229mm)
12"
(305mm)
6" + 9"
(152 + 229mm)
6" + 12" / 9" + 9"
17" - 24" Adj. Pipe
(432 - 610mm)
(279 - 372mm)
6" + 9"
(152 + 229mm)
6" + 12" / 9" + 9"
17" - 24" Adj. Pipe
(432 - 610mm)
(279 - 372mm)
77045

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dv1000dspDv1200dsnDv1400dspDv1200dspDv1400dsn

Table of Contents