Temco DV5200DSN Homeowner's Installation & Operation Manual

Direct vent zero clearance gas fireplace heater

Advertisement

Quick Links

INSTALLER/CONSUMER

SAFETY INFORMATION

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified in-
staller, service agency or the
gas supplier.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your
building.
Immediately call your gas
supplier from your neighbor's
phone. Follow the gas suppliers
instructions.
If you cannot reach your gas
supplier call the fire department.
DO NOT STORE OR USE GASO-
LINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY
OTHER APPLIANCE.
WARNING: Improper installation,
adjustment, alteration, service or
maintenance can cause injury or
property damage. Refer to this
manual. For assistance or additional
information, consult a qualified
installer, service agency or the gas
supplier.
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
Direct Vent Zero Clearance
Gas Fireplace Heater
Models: DV5200DSN, DV5200DSP
DV6400DSN, DV6400DSP
Homeowner's Installation and
Operating Manual
U.S. Patents: 5,669,374; 5,562,088; 6,138,667: Can. Patent: 2,139,684
CFM Specialty Home Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
5L24
77794 2/04 Rev. 21

Advertisement

Table of Contents
loading

Summary of Contents for Temco DV5200DSN

  • Page 1: Safety Information

    WARNING! Direct Vent Zero Clearance IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED Gas Fireplace Heater EXACTLY, A FIRE OR EXPLO- Models: DV5200DSN, DV5200DSP SION MAY RESULT CAUSING PROPERTY DAMAGE, PER- DV6400DSN, DV6400DSP SONAL INJURY OR LOSS OF LIFE.
  • Page 2: Table Of Contents

    Temco DV5200, DV6400DSN/DSP Series Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Specialty Home Products fireplace. While we have written these instructions as accurately and thoroughly as possible, they may not cover every system, variation or contingency.
  • Page 3: Installation & Operating Instructions

    It is performed by a qualified installer, service agency or gas not unusual for your Temco Fireplace Products gas supplier. A professional service person should be con- fireplace to give off some odor the first time it is tacted to inspect this fireplace annually.
  • Page 4: Fireplace Dimensions

    Temco DV5200, DV6400DSN/DSP Series Fireplace Dimensions 4" (102mm) Dia. Rough 7" (178mm) Dia. Opening Depth Bottom Gas Line Access S - Rough Opening Width Rough Opening Height Gas Line J Box J Box Access Access Access Line Access NOTE: Flex pipe diameters are 4”...
  • Page 5: Locating Your Fireplace

    Temco DV5200, DV6400DSN/DSP Series Firestop/Wall Sleeve Locating Your Fireplace VEF (Vinyl Siding) or BEF (Brick) Extension Flange Vent Terminal 10³⁄₄" Standoff (273mm) Min. 41³⁄₈" (1051mm) 30⁵⁄₈" (778mm) 35³⁄₄" (908mm) U584-1 Fig. 2 Locate gas fireplace. A) Flat on wall B) Cross Corner C) As an Island 21¹⁄₂"...
  • Page 6: Clearance To Combustibles

    Temco DV5200, DV6400DSN/DSP Series WARNING: Combustible objects must not be placed Clearance to Combustibles on a noncombustible mantel unless the noncombus- tible mantel meets the minimum height and width Top of unit to ceiling* ....... 36” (914mm) requirements for a combustible mantel.
  • Page 7: Gas Specifications

    Temco DV5200, DV6400DSN/DSP Series 1. The gas pipeline can be brought in through the Combustible Material bottom or the right or the left side of the appliance. 2 x 4 Stud A hole is provided at all locations to allow for the gas pipe installation and testing of any gas connec- tion.
  • Page 8: Sediment Trap

    1. Temco 4” x 7” dia. flex vent. It is recommended that the termination not be located 2. Temco TDV series 4” x 7” dia. rigid vent. within 24" (305mm) of garden sheds, fences, decks, 3. Simpson Dura-Vent GS series 4” x 6⁵⁄₈” dia. vent.
  • Page 9: General Venting Information - Termination Location

    Temco DV5200, DV6400DSN/DSP Series General Venting Information - Termination Location INSIDE CORNER DETAIL Fixed Fixed Closed Closed Fixed Operable Closed AREA WHERE TERMINAL IS NOT PERMITTED VENT TERMINATION AIR SUPPLY INLET CFM145a Canadian Installations US Installations A = Clearance above grade, veranda, porch, 12”...
  • Page 10 Temco DV5200, DV6400DSN/DSP Series NOTE: Use only venting systems and components as certified with the appliance. Use of uncertified vent systems or components will void the warranty and may compromise the operation of the fireplace, its systems, and components as certified with the appliance.
  • Page 11: Sidewall (General)Venting Information

    Temco DV5200, DV6400DSN/DSP Series Sidewall (General) Venting Information Flex Venting Refer to Page 19 for venting components list. Vent Opening for Combustible Wall • Flex vent shall use the spacer springs as included 9³⁄₄" every foot to ensure proper vent operation.
  • Page 12: Sidewall (Horizontal) Venting

    Temco DV5200, DV6400DSN/DSP Series Sidewall (Horizontal) Venting Firestop/Wall Sleeve (Included with HFTK) Exterior Wall GFP74FV3 (3’ For side wall (Horizontal) venting, this appliance is VEF (or BEF) (914mm) Flex Pipe Vinyl (or Brick) approved for use with a 7" x 4" flexible venting system 4”...
  • Page 13: Flex Vent Through The Roof (Vertical) Applications

    Temco DV5200, DV6400DSN/DSP Series Inside Wall Exterior Wall Wall Terminal Shield Assembly Flange at Top 2" (51mm) 1" (25mm) Band Clamp 10¹⁄₂" Flex Duct Thimble Extension (267mm) T188 Fig. 21 Secure vent cap terminal to exterior wall. 7” (178mm) Band Collar 4”...
  • Page 14: Vsk7 Vertical Flex Vent Kit Installation

    Temco DV5200, DV6400DSN/DSP Series The VSK7 Kit contains: Attic Above Ceiling (Uninsulated) • Vertical Termination Cap and Storm Collar Firestop • 4”/7” dia. x 24” Rigid Pipe (unitized) • 7” dia. Roof Support Components • 0/12-5/12 Flashing with Storm Collar •...
  • Page 15: Tdv Series Direct Vent System Installation

    Refer to Page 19 for venting components list. • The TDV series vent system is specifically approved only for Temco Direct-Vent fireplace models with a 4” (102mm) diameter flue and a 7” (178mm) diam- eter inlet vent system. The use of uncertified venting will void warranties and may compromise the operation and safety of the appliance.
  • Page 16: Through The Roof (Vertical) Venting

    Temco DV5200, DV6400DSN/DSP Series Elbows & Offsets - General Each installation assures the use of one 45° elbow 3³⁄₈" (86mm) horizontal or vertical (off top of unit). 8" (203mm) Sidewall (Horizontal) Venting Information 7⁷⁄₈" (200mm) 1. Make sure fireplace location and termination loca- 9¹⁄₈"...
  • Page 17 Temco DV5200, DV6400DSN/DSP Series ATTENTION: Vent terminal flue and inlet pipes must 9. Using the high temperature sealant provided, apply overlap last vent section a minimum of 1” (25mm). a small bead of sealant to both the flue and inlet...
  • Page 18 Temco DV5200, DV6400DSN/DSP Series Corner Installation Up & Out Vent Horizontal Vent Horizontal 10" (254mm) HSQ47 Min. HSQ47 TDV90 TDV45 Min. TDV90 TDV45 (Ref.) Min. 45° M* Min. N Max. Horizontal Vent Vertical Vent Cap telescopes may be cut off to achieve HSQ47 minimum framing depth.
  • Page 19: Venting Components

    (Used with 7” dia. pipe (75783) system only) (76049) system only) (76048) T199 Temco Flex Vent Termination Kits Available Square Horizontal Cap (uses 7/4 Flex) HFTK Round Hor. Term. Cap (High Wind) (Includes 7/4 Flex x 3 ft. long) CDV-HSK Round Hor.
  • Page 20 Many items are offered in decorative black, as well as 12¹⁄₂” - 14” 9” galvanized finish. The galvanized finish may be used (318 - 356mm) (229mm) for installation with your Temco gas fireplace. 15¹⁄₂” - 17” 12” The minimum components required for a basic horizon- (394 - 432mm) (305mm) tal termination are: 14¹⁄₂”...
  • Page 21 48” Pipe Length - Galvanized Wall Penetration Heat Shield (Wall Thimble) 48” Pipe Length - Black 902B Parts Available from TEMCO (Not supplied by 11” - 14B\,” Adjustable Pipe - Black 911B Dura-Vent) 17” - 24” Adjustable Pipe - Black...
  • Page 22 (Horizontal Venting) SV4E40AT* 36” Pipe Length - Galvanized SV4L36 48” Pipe Length - Black SV4LB48 48” Pipe Length - Galvanized SV4L48 *NOTE: This adapter elbow is required on all TEMCO Direct Vent Fireplaces for installation of Secure Vent Systems. 77794...
  • Page 23: Operating Instructions

    Identify this area installed. Various styles and finishes are available as and install the door with this area at the top. options. Contact your nearest Temco dealer/distributor Glass Door Removal Procedure for information on the Grill Kits available.
  • Page 24: Log Installation

    Temco DV5200, DV6400DSN/DSP Series Bracket Support Slot T202 Fig. 31 Louvre in place. Log Installation TL122 Fig. 33 DV5200 logs, side view. Attention: Glass door should be removed when installing logset and prior to lighting the unit. 1. Remove glass door (Refer to “Glass Door Removal Procedure”)
  • Page 25: Speed Control Switch

    Temco DV5200, DV6400DSN/DSP Series 6. Unpack steel wool and cut off a 1” x 3” (25 x 76mm) CAUTION: Should this fan require ser- strip. Save the remainder of the steel wool for future vicing, the power supply must be discon- use.
  • Page 26: Lighting & Operating Instructions

    Temco DV5200, DV6400DSN/DSP Series Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. B. Use only the wall switch or remote control switch A.
  • Page 27: Troubleshooting

    Temco DV5200, DV6400DSN/DSP Series Troubleshooting NOTE: Before troubleshooting the gas control system, be sure external shut off is in the “ON” position. WARNING: Before doing any gas control service work, remove glass front! Problem Possible Cause Solution No gas to main burner...
  • Page 28: Fuel Conversion

    Temco DV5200, DV6400DSN/DSP Series Fuel Conversion Instructions The conversion shall be carried out in accordance 1/8” When Gas Tight with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CSA B149.2 installation Code...
  • Page 29 Temco DV5200, DV6400DSN/DSP Series Regulator Fitting Air Shutter Settings Model Opening A DV5200DSP 7/16” (11mm) DV6400DSP 7/16” (11mm) T210 Fig. 42 Correct air shutter settings. NOTE: These are minimum settings. Air shutter open- Fig. 41 White-Rodgers 25M18A-706PI gas control. ings may be increased to prevent flame sooting.
  • Page 30: Maintenance

    Temco DV5200, DV6400DSN/DSP Series Maintenance Once installed, the unit should be operated at least High Altitude three (3) times to ensure that all is in working order. When installing this fireplace at an elevation between 0 NOTE: Manufacturing oils will smoke during initial and 2000 feet (0 - 610m) in the USA and 0 and 4500 firing of appliance.
  • Page 31: Glass Door Replacement

    Gas Code) Glass Door Replacement Burner, Pilot, Firebox and Logs Only Temco parts should be used. Contact your CAUTION: Before cleaning or moving logs nearest Temco dealer for replacement parts. Refer to or other parts of the unit, be sure to read the Replacement Parts list on Page 33.
  • Page 32 Temco DV5200, DV6400DSN/DSP Series Normal and High Direct Vent Units - Inputs - Orifice Size - Altitude BTU/Hr BTU/Hr Manifold Pressure Orifice 0 - 2000ft. Altitude in USA Model Min. Input Max. Input @ Max. Orifice 0-4500ft Altitude in Canada...
  • Page 33: Replacement Parts

    Temco DV5200, DV6400DSN/DSP Series Replacement Parts DV5200, DV6400 Description DV5200 DV6400 Burner 77440 77440 Gasket Tape 5/8” Wide 75279 75477 Gas Valve (White-Rodgers) 78581 78581 Glass Door Assembly 75362 75372 Log Set 78369 76761 Log, Front 76895 76893 Log, Back...
  • Page 34: Warranty

    Limited Warranty TEMCO Fireplace Products Direct Vent Gas Fireplaces and Startup Checklist, a copy of which must be This warranty is limited to TEMCO Fireplace Products submitted along with proof of purchase, to obtain Direct Vent Gas Fireplaces (henceforth, Product) manu-...
  • Page 35: Installation And Startup Checklist

    INSTALLATION AND STARTUP CHECKLIST Customer Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance in- staller. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Ser- vices for prior written approval of warranty repair or replacement.
  • Page 36 INSTALLATION AND STARTUP CHECKLIST Installer’s Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement.
  • Page 37: Warranty Registration

    Mississauga, Ontario Canada L5T 2N6 Serial # ______________________________________ Model # ______________________________________ I certify that I have followed all codes and regulations and adhered to the TEMCO installation instructions. I have completed the proper installation and startup checklist. Installer’s Signature Print Installer’s Name...
  • Page 38 CFM Specialty Home Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777...

This manual is also suitable for:

Dv5200dspDv6400dsnDv6400dsp

Table of Contents