Temco DV1000N/P Installation And Operating Manual

Direct vent zero clearance gas fireplace heater

Advertisement

INSTALLER / CONSUMER

SAFETY INFORMATION

PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSON-
AL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or the
gas supplier.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
your neighbor's phone. Follow the gas
suppliers instructions.
• If you cannot reach your gas supplier
call the fire department.
DO NOT STORE OR USE GASO-
LINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTH-
ER APPLIANCE.
WARNING: Improper installation, ad-
justment, alteration, service or main-
tenance can cause injury or property
damage. Refer to this manual. For
assistance or additional information,
consult a qualified installer, service
agency or the gas supplier.
U.S. Patents: 5,669,374; 5,562,088; 6,138,667;
Can. Patent: 2,139,684
Direct Vent Zero Clearance
Gas Fireplace Heater
Models:
DV1000N/P, DV1200N/P, DV1400N/P
Homeowner's Installation and
Operating Manual
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
76657
DV1000/1200/1400
cover
12/2/03 djt
C
US
76657 5/08 Rev. 31

Advertisement

Table of Contents
loading

Summary of Contents for Temco DV1000N/P

  • Page 1: Safety Information

    INSTALLER / CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE Direct Vent Zero Clearance WARNING! Gas Fireplace Heater IF THE INFORMATION IN THIS Models: MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO- DV1000N/P, DV1200N/P, DV1400N/P SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSON- AL INJURY OR LOSS OF LIFE.
  • Page 2: Table Of Contents

    Temco DV1000/1200/1400 Series Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Temco Fireplace Products fireplace. While we have written these instructions as accurately and thoroughly as possible, they may not cover every system, variation or contingency.
  • Page 3: Installation & Operating Instructions

    Temco DV1000/1200/1400 Series Installation & Operating Instructions This gas appliance should be installed by a qualified 12. Do not operate appliance unless completely installed as per installation instructions. installer in accordance with local building codes and with 13. This appliance may be used in a bedroom installation. Install current CSA-B149.1 Installation codes for Gas Burning in accordance with local building codes and regulations.
  • Page 4: Requirements For The Commonwealth Of Massachusetts

    Temco DV1000/1200/1400 Series Installation & Operating Instructions Inspection Requirements for the Commonwealth of Massachusetts The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not All gas fitting and installation of this heater shall only be approve the installation unless, upon inspection, the done by a licensed gas fitter or licensed plumber.
  • Page 5: Fireplace Dimensions

    Temco DV1000/1200/1400 Series Fireplace Dimensions 4" (102 mm) Dia. Rough 7" (178 mm) Dia. Opening Depth Bottom Gas Line Access S - Rough Opening Width Rough Opening Height Gas Line J Box J Box Access Access Access Line Access NOTE: Flex pipe dimaeters are 4”...
  • Page 6: Locating Your Fireplace

    Temco DV1000/1200/1400 Series Firestop/Wall Sleeve Locating Your Fireplace VEF (Vinyl Siding) or BEF (Brick) Combustible Extension flange Construction Allowed Vent Terminal 10³⁄₄" Standoff (273mm) Min. LU584-1 LU584-T Fig. 2 Locate gas fireplace. Locating unit A) Flat on wall B) Cross Corner C) As an Island 12/18/02 djt D) As a room divider E) Flat on wall corner F) Exterior wall...
  • Page 7: Clearance To Combustibles

    Temco DV1000/1200/1400 Series 5. Drywall can be extended flush on the bottom, top and to the outermost part of the sides of the fire- place. 6. Noncombustible materials such as brick and tile can be extended across the face of the fireplace. If brass trim kit is going to be installed, brick and tile will have to be installed flush with the front of this appliance.
  • Page 8: Gas Specifications

    Temco DV1000/1200/1400 Series tighten the flexible tube at the shut off valve and Combustible Material at the gas control. 2 x 4 Stud 3. When using a flex connector,* use only approved fittings. When a union is installed, provide easy access in it’s placement for servicing.
  • Page 9: General Venting

    Temco DV1000/1200/1400 Series General Venting When locating the vent termination, the minimum vent These fireplaces are certified for use with four types of clearances must be observed. (Page 10, Fig. 9) venting systems 1. Temco 4” x 7” dia. flex vent. NOTE: Local codes may require different clearances.
  • Page 10: General Venting Information - Termination Location

    Temco DV1000/1200/1400 Series General Venting Information - Termination Location INSIDE CORNER DETAIL Fixed Fixed Closed Closed Fixed Operable Closed AREA WHERE TERMINAL IS NOT PERMITTED VENT TERMINATION AIR SUPPLY INLET CFM145a Canadian Installations US Installations A = Clearance above grade, veranda, porch, 12”...
  • Page 11: Termination Clearances

    Temco DV1000/1200/1400 Series Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony - Balcony - with perpendicular side wall with no side wall = Min.
  • Page 12: Sidewall (General)Venting Information

    Temco DV1000/1200/1400 Series Vent Opening for Combustible Wall 9³⁄₄” (248 mm) 5⁷⁄₈” (149 mm) 10³⁄₄” (273 mm) 4⁷⁄₈” (124 mm) Framing Detail Fireplace Hearth Opening for Noncombustible Wall NOTE: Apply sealant “Mill-Pac” to inner pipe and “Mill-Pac” or high temperature silicone sealant to outer pipe. Sealant should be ap- plied at every joint in the vent system including at the fireplace and Rnd.
  • Page 13: Sidewall (Horizontal) Venting

    Temco DV1000/1200/1400 Series • Lengths of co-axial flex may be joined together using HFTK (Trapezoid Termination Cap) ◆ a flex connector kit (GFPVCK) only, maximum 1 kit The vent starter kit contains the following: per installation. • Horizontal termination An extension collar is included with side wall cap kits to •...
  • Page 14 Temco DV1000/1200/1400 Series No more than (4) 90° and (2) 45° offsets are to be used per installation. Vent terminal cap location should be in accordance with the Venting Graph chart and the Verti- cal Termination Location information. 1. Measure the total wall thickness. Determine whether or not the thimble extension is needed.
  • Page 15: Flex Vent Through The Roof (Vertical) Applications

    Temco DV1000/1200/1400 Series 8. To finish connections, place a small bead of silicone to the outside of the fireplace inlet flange. Then, slide the extension collar over the inlet flange and secure Roof with the three (3) screws provided. NOTE: We recommend driving in two (2) sheet metal 6' (1.8m) screws at 180°...
  • Page 16: Tdv Series Direct Vent System Installation

    Temco DV1000/1200/1400 Series tion and building materials. An attic insulation shield VT47 Vertical (AS7-8) may be used above the firestop to keep attic Vent Cap insulation spaced away from the vent system. 8. Rigid pipe section included with vertical termination must be used in conjunction with the roof support so that the termination is secure in winds.
  • Page 17: Through The Roof (Vertical) Venting

    Temco DV1000/1200/1400 Series blockage of venting system. When using snow blowers, IMPORTANT: Do not mix vent system compo- make sure snow is not directed towards vent termina- nents with components for other vent systems. tion area. The TDV series is considered a “special vent system”. NOTE: Use only venting systems and components Check with local codes or in the absence of same, with as certified with the appliance.
  • Page 18 Temco DV1000/1200/1400 Series ATTENTION: Vent terminal flue and inlet pipes must 5. Align the flue and inlet pipes of each vent section overlap last vent section a minimum of 1” (25 mm). to the mating component, then slide the sections together.
  • Page 19: Corner Installation

    Temco DV1000/1200/1400 Series Corner Installation Up & Out Vent Horizontal Vent Horizontal 10" (254mm) HSQ47 Min. HSQ47 TDV90 TDV45 Min. TDV90 TDV45 (Ref.) Min. M* Min. N Max. Horzontal Vent Vertical Vent Cap telescopes may be HSQ47 cut off to achieve mini- 16¹⁄₃₂"...
  • Page 20 Temco DV1000/1200/1400 Series Simpson Dura-Vent Venting Flat Wall Installation (All Units) Horizontal or Vertical Terminations Wall Thickness Vent Length inches (mm) Required (inches(mm)) The Simpson Dura-Vent Direct Vent System (GS 4” 5¹⁄₂” - 7” x 6⁵⁄₈”) offers a complete line of component parts for (140 - 178 mm) installation of both horizontal and vertical installations.
  • Page 21 Temco DV1000/1200/1400 Series Flexible Venting Individual System Components Vent Kit Storm Collar HFTK GFP74FV3 3’ (914 mm) Vinyl Extension (Used with 7” dia. GFP74FV10 10’ (3 m) Horizontal Flex Frame Kit pipe system only) Terminal Kit GFP74FV20 20’ (6 m) (For use with HFTK) (760505) (76478)
  • Page 22 Temco DV1000/1200/1400 Series Vent Guard Vertical Termination Vertical Termination Storm Collar Horizontal Termination Cap (Part #984) Adjustable Flashing Vinyl Siding Standoff 0/12 to 6/12 (Part #950) (Optional) Wall Penetration Heat Shield (Wall thimble) Pipe Length (Part #942) (Refer to Parts List) Elbow Alternate Snorkel Termination Cap Pipe Length...
  • Page 23: Venting Components

    Temco DV1000/1200/1400 Series Secure Vent Venting Components 1¹⁄₂” - 6” Adjustable Pipe - Black SV4LBA Standard Horizontal Kit SV0SHK Includes: 90° Swivel Black Elbow 1¹⁄₂” - 6” Adjustable Pipe - Galvanized SV4LA 1¹⁄₂” - 12” Adjustable Pipe - Black SV4LBA12 Decorative Black Plate 1¹⁄₂”...
  • Page 24: Operating Instructions

    Temco DV1000/1200/1400 Series Operating Instructions household cleansers and warm water. After that, the WARNING: Do not operate appliance with the glass glass should be cleaned two or three times a season front removed, cracked or broken. depending on the amount that the fireplace is used. •...
  • Page 25: Log Installation

    Temco DV1000/1200/1400 Series 9. Replace glass door. The door must be installed be- After completing Steps 1 and 2, the louvre assembly fore operating the fireplace. (Refer to Page 24) should look like the illustration shown in Figure 31. 10. Flame should not impinge (touch) on logs. Models DV1000, DV1200 and DV1400: To install the WARNING: Do not place rock wool, lava rock bottom louvre assembly, hook the top louvre blade ends...
  • Page 26: Thermostatic Fan Kit - Optional

    Temco DV1000/1200/1400 Series Speed Control Switch 1. The blower combination on/off switch and electronic speed control is supplied loose to allow mounting in a conveniently located wall mounted electrical box. 2. Wire speed control into black (hot) side of 120V, 60Hz line as shown in blower wiring diagram.
  • Page 27: Managing Heat Output

    Temco DV1000/1200/1400 Series Fan Operation Wall Switch (not supplied) The fan operates automatically - turn the knob on the Thermopile speed control to adjust to the desired speed. The fan Pilot will turn on as the fireplace comes up to operating tem- Pilot Screw Ignitor perature.
  • Page 28: Lighting & Operating Instructions

    Temco DV1000/1200/1400 Series Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lit instructions.
  • Page 29: Troubleshooting

    Temco DV1000/1200/1400 Series Troubleshooting SIT Millivolt Valve NOTE: Before troubleshooting the gas control system, be sure external shut off is in the “ON” position. WARNING: Before doing any gas control service work, remove glass front! Table 1 Valve Type Main Operator Safety Magnet NOVA MV Plus Minimum Voltage...
  • Page 30 Temco DV1000/1200/1400 Series System Checks (continued) Problem Possible Cause Solution Defective thermocouple. Verify that thermocouple is not kinked or damaged. (mv Plus systems) Check open circuit voltage of thermocouple. Voltage should be between 18mv and 28mv. If voltage is less than 14mv, replace thermocouple. Defective thermo-generator.
  • Page 31 Temco DV1000/1200/1400 Series System Checks (continued) Problem Possible Cause Solution Thermo-generator output After the pilot has been lit for approximately three voltage not within design minutes, and only the thermo-generator wire con- parameters. nected to the main operator head, measure the voltage acrossTPTH and TP.
  • Page 32: Maintenance

    Temco DV1000/1200/1400 Series Maintenance High Altitude Once installed, the unit should be operated at least three (3) times to ensure that all is in working order. When installing this fireplace at an elevation between NOTE: Manufacturing oils will smoke during initial firing 0 and 2000 feet (0 - 610m) in the USA and 0 and 4500 of appliance.
  • Page 33 Temco DV1000/1200/1400 Series Cleaning After the logs are removed allowing access to the burn- er area, use a vacuum cleaner to carefully remove dust This unit should be cleaned and serviced by a Qualified and loose particles from the base, logs and from around Gas Technician at least annually.
  • Page 34: Air Shutter

    Temco DV1000/1200/1400 Series Normal and High Direct Vent Units - Inputs - Orifice Size - Altitude BTU/Hr BTU/Hr Manifold Pressure Orifice 0 - 2000ft. Altitude in USA Model Min. Input Max. Input @ Max. Orifice 0-4500ft Altitude in Canada DV1000N 12,500 18,500 3.5”w.c.
  • Page 35: Replacement Parts

    Temco DV1000/1200/1400 Series DV1000 / DV1200 / DV1400 Replacement Parts Ref. Description DV1000 DV1200 DV1400 Burner 75470 75470 75470 Gasket Tape 5/8” Wide 75449 75448 75447 Gas Valve LP (SIT) 76448 76448 76448 Gas Valve NG (SIT) 76449 76449 76449 Glass Door Assembly 75374 75373...
  • Page 36: Warranty

    Temco DV1000/1200/1400 Series Limited Warranty TEMCO Fireplace Products Direct Vent Gas Fireplaces The installer must have completed the installation This warranty is limited to TEMCO Fireplace Products and Startup Checklist, a copy of which must be Direct Vent Gas Fireplaces (henceforth, Product) manu- submitted along with proof of purchase, to obtain factured by CFM Specialty Home Products (hence- prior approval for warranty repair or replacement...
  • Page 37: Installation And Startup Checklist

    Temco DV1000/1200/1400 Series TEMCO FIREPLACE PRODUCTS DIRECT VENT FIREPLACES INSTALLATION AND STARTUP CHECKLIST Customer Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement.
  • Page 38 Temco DV1000/1200/1400 Series TEMCO FIREPLACE PRODUCTS DIRECT VENT FIREPLACES INSTALLATION AND STARTUP CHECKLIST Installer’s Copy NOTE: TEMCO Fireplace Products gas logs and fireplaces require installation by a qualified gas appliance installer. A copy of this checklist must be submitted, along with proof of purchase, when applying to Technical Services for prior written approval of warranty repair or replacement.
  • Page 39: Warranty Registration

    Temco DV1000/1200/1400 Series Customer Copy Serial # ______________________________________ Model # ______________________________________ I certify that I have followed all codes and regulations and adhered to the TEMCO Fireplace Products installation instructions. I have completed the proper installation and startup checklist. Installer’s Signature Print Installer’s Name Purchaser _____________________________________ WARRANTY REGISTRATION...
  • Page 40 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com...

Table of Contents