Thermostat Installation - Quadra-Fire Castile Insert Pellet 810-02901 (MBK) Owner's Manual

Castile pellet insert installation and operation
Hide thumbs Also See for Castile Insert Pellet 810-02901 (MBK):
Table of Contents

Advertisement

R
H. Thermostat Installation
1
A 12 volt AC thermostat is required to operate this
.
pellet appliance. You may use the included wall mount
thermostat or purchase an optional programmable
thermostat or remote control. The included thermostat
is equipped with an adjustable heat anticipator. The
current rating is .05 amps. The anticipator needs to
be adjusted to the lowest setting available.
2.
When mounting a thermostat on a wall, be sure to follow
your thermostat installation instructions carefully.
NOTE: Thermostat must be mounted level for accu-
rate readings. The thermostat should be mounted
on an inside wall and not in direct line with the
appliance convection air. Remove any packaging
from inside the thermostat before using.
NOTE: If the thermostat is located too close to
the appliance, you may need to set the tempera-
ture setting slightly higher to maintain the desired
temperature in your home.
3.
There is a 4 screw terminal block located on the junc-
tion box to the left of the power cord inlet. The center
2 screws are for the thermostat wires. The outer 2 are
the mounting screws for the terminal block. Figure
21.1.
Figure 21.1
September 1, 2008
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
Red all
Lig t
se
eat
tp t
S it
Reset
tto
250-7251F
Castile Pellet Insert
CAUTION
o trol o
o er ord
tlet
T ermostat
lo
tio
o
Page 21