G. Optional Log Set Placement Instructions
2 PIECE LOG SET INSTALLATION
1. Place the left log as shown. There are 2 indentations in
the bottom of the log to fi t over the screw heads in the
fi rebox. Figures 21.1 and 21.2.
2. Place the right log in front of the 2 screw heads in the
fi rebox. Figures 21.3 & 21.4.
CAUTION
Logs are FRAGILE. Use extreme care when handling or
cleaning logs.
Left Log
Log fits over screws
Figure 21.1
Right Log
Log rests in front of screws
Figure 21.3
NOTICE:
Due to the abrasive nature of a pellet appliance fi re, the logs
are not covered under warranty. Any placement variation
other than shown here can cause excessive heat and shall
void the appliance warranty.
H. Wall Control Thermostat Installation
1.
When mounting the wall control thermostat on the wall,
be sure to follow your wall control's installation instruc-
tions carefully.
NOTE: The wall control thermostat should be mount-
ed on an inside wall and not in direct line with the
appliance convection air.
NOTE: If the wall control thermostat is located too
close to the appliance, you may need to set the
temperature setting slightly higher to maintain the
desired temperature in your home.
2.
There is a 5 screw terminal block located at the lower
left of the appliance, behind the cast side.
May 5, 2015
Log has indentations on the
bottom to fit over the screw
heads.
Figure 21.2
Figure 21.4
The center 3 screws are for the wall control thermostat
wires and the 2 outer screws are mounting screw and
should not have wires attached to them.
The thermostat wires are color coded. The green wire
is on the top, the white in the middle and the red on the
bottom. Figure 21.5
There are colored dots corresponding with the same
colored wire on the right side which are easily seen by
the installer. If by chance it is put in upside down the
dots will be on the left side and will not be visible.
Shock hazard.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
12 volt power inlet (for
optional battery back-up)
Household power inlet
Thermostat wires in center 3 screws
Figure 21.5
7036-188E
MT VERNON AE INSERT
CAUTION
Green wire
White wire
Red wire
21