Maintenance Of Projector

Maintenance of Projector
Filter
Keep the air filters clean by cleaning them periodically.
By using Filter Counter the projector can remind you of the timing.
There are 2 types of air filters in this projector, one is black sponge attached just back
side of the filter cover and the other is the filter assembly called Anti-dust filter(consists
of a white folded cloth and black frame).
How to clean or replace the filters
Turn off the projector, and unplug the power cord. Wait to allow the projector to cool
down sufficiently.
1. Push up 2 white stoppers of the Filter cover and remove it from the side of projector
as shown below.
2. R emove the Anti- dust filter from the Filter cover by pushing and sliding it as shown
below. (There is >ABS< sign on the top the black frame of the Anti-dust filter.)
3. C lean the filters with a vacuum cleaner except for the back side of the sponge,
because the vacuum cleaner may suck it. Brush the sponge gently by a brush.
(Do not clean the filters with water.)
*If the Anti-dust filter is too dirty to clean, please replace it with new one.
The part number of the Anti-dust filter is "13340233".