Table 34 MPX200 log messages (continued)
41284
QLIS_LoginPduContinue: Session
does not exist, invalid TSIH
0x%x
41353
QLIS_LoginPduContinue: Session
does not exist, invalid TSIH
0x%x
41354
QLIS_LoginPduContinue:
Unexpected CHAP key detected
41508
QLBI_SetPortInfo:
QLUT_AllocatePortalObject
failed (PortType 0x%x, PortId
0x%x)
41626
QLBI_GetLunInfo: INQUIRY
failed, TPB status 0x%x
41629
QLBI_GetLunInfo: INQUIRY
failed, TPB status 0x%x
41635
QLBI_Passthru: Invalid data
length %d bytes
41636
QLBI_GetLunInfo: INQUIRY
failed, TPB status 0x%x
41696
QLBI_GetLunInfo: INQUIRY
failed, TPB status 0x%x
41700
QLBI_Passthru: Invalid CDB
length %d bytes
41701
QLBI_Passthru: Invalid data
length %d bytes
41717
QLBI_Passthru: Invalid data
length %d bytes
41750
QLBI_Ioctl: ERROR: Operation
(0x%x) not supported in this
mode
41768
QLBI_GetLunList: REPORT LUNS
command failed
218
Log messages
(router is target) in subsequent login
PDUs.
App
Error
iSCSI login PDU was received with an
invalid TSIH value. The TSIH is invalid
because there is no session with that
TSIH value. This would occur if the
iSCSI initiator attempting the login
failed to used the TSIH value provided
in the target login response PDU
(router is target) in subsequent login
PDUs.
App
Error
iSCSI login rejected due to a CHAP
authentication error.
App
Error
iSCSI login rejected due to a CHAP
key error.
App
Error
Failed to allocate an object for Set Port
Info IOCTL processing: PortType: 0 =
FC, 1 = iSCSIPortId: 0 = FC1 or
iSCSI1(GE1), 1 = FC2 or iSCSI2
(GE2)
App
Error
Inquiry command failed. The Inquiry
command was issued by the router as
part of its discovery process.
App
Error
Pass-Through command for Inquiry
command for page 83 failed. The
Inquiry command was issued by the
router as part of its discovery process.
App
Error
Pass-Through command for Read
Capacity command failed. The Read
Capacity command was issued by the
router as part of its discovery process.
App
Error
Read Capacity command failed. The
Read Capacity command was issued
by the router as part of its discovery
process.
App
Error
Pass-Through command issued by
management application (such as GUI)
was aborted.
App
Error
Pass-Through command issued by
management application (such as GUI)
failed due to invalid CDB length.
App
Error
Pass-Through command issued by
management application (such as GUI)
failed due to invalid data length.
App
Error
Pass-Through command issued by
management application (such as GUI)
was interrupted or timed out.
App
Error
IOCTL operation unsupported.
Operation code provided in log
message.
App
Error
Report LUNs command failed. The
Report LUNs command was issued by

Advertisement