Installing the Honeywell IP Utility and the Web-Client Software
40
Figure 3-4
Set the IP Network Settings Automatically or Manually
Updating IP Network Settings Automatically
1.
In the Discovery pane, select the device and click Connect
2.
From the System tab click the Obtain an IP Address automatically check box.
3.
Enter a Device Name, for example,
4.
Click Apply.
The network automatically assigns the IP Address based on the DHCP network server
details. If no DHCP server is present on the network, the hardware defaults to an
APIPA address (169.254.x.x).
Updating IP Network Settings Manually
Caution
When manually updating the network settings, it is important to enter
the correct IP network settings before applying them. Incorrect values
might cause a failure when connecting to the device. See
for definitions of each setting.
1.
In the Discovery pane, select the device, and click Connect
2.
To assign a static IP address for the device, in the System tab click to clear the
Obtain an IP Address automatically check box.
3.
Enter a Device Name, for example, FrontLobby01.
Note
The MAC address is a factory-assigned address that is unique for each
device.
Click to clear this checkbox and
manually set the network details
FrontLobbyDome01.
.
Table 3-4
.