the rotary seat is no longer above the
negative terminal.
E
Connect the negative terminal clamp.
E
Connect breather hose 4 to the front
end of the battery.
E
Tighten the securing screws.
The retainer plate is secured to prevent
slipping.
E
Refit the seat base cover.
E
Turn the rotary catch of the cover
clockwise.
i
After the battery has been reconnected,
you must readjust the electric sliding door
e
(
page 68).
Additional battery
The additional battery is located in the
base of the co-driver's seat.
You will find information on how to remove
and fit the battery in the "Starter battery"
e
section (
page 259).
Care of batteries
!
Please note the following points:
I
Dirty terminal clamps and battery surfaces
cause leaks, which lead to the batteries dis-
charging. Always keep the terminal clamps
and battery surfaces clean and dry. Lightly
grease the terminal clamps, particularly the
undersides, with acid-proof grease.
I
Cleaning agents containing fuel corrode the
battery housing. Only clean with commer-
cially available cleaning agents and only
clean the battery casing with the cell caps
screwed in. Otherwise, dirt could get into
the battery cells.
I
The vent holes in the cell caps must be un-
obstructed and the cell ventilation hoses
must not be blocked. Otherwise, gas cannot
escape. Clean blocked vent holes with a
suitable implement, e.g. a piece of wire.
You must unscrew the cell caps first. There
is otherwise a risk of a short circuit.
Check the terminal clamps and the fasten-
I
ing of the negative cable to the chassis at
regular intervals to ensure that they are cor-
rectly seated.
I
Batteries which are out of use should be re-
charged once a month.
Nur fuer internen Gebrauch
Operation
Maintenance
4
261
Need help?
Do you have a question about the Vito and is the answer not in the manual?