Display messages

Message

(Reset)

(Serial reset)



(Lamp error)

(Memory error)

(Check-sum error)
   

(Short error)

(Base temperature sensor error)

(Head temperature sensor error)

(Lamp temperature sensor error)

(Switchmode/ballast side
temperature sensor error)

(Feedback error pan)

(Feedback error tilt)

(Feedback error pan/tilt)

(Pan time-out)

(Tilt time-out)

(Focus time-out)

(Zoom time-out)

(Color wheel time-out))

(Gobo wheel 1 time-out)

(Gobo wheel 2 time-out)

(Gobo wheel rotation time-out)

(Animation wheel position
time-out)

(Animation wheel rotation
time-out)

(Cyan time-out)

(Magenta time-out))

(Yellow wheel time-out)


Appears when...
... the fixture is indexing effects at startup.
... the fixture has received a reset command.
... the effects have been indexed and are
moving to their default positions.
...the lamp access cover is not fully closed.
... the lamp does not ignite within 30 seconds
of receiving the 'Lamp ON' command. Likely
reasons are a missing or defective lamp, or
insufficient AC voltage.
...the EEPROM memory cannot be read.
...a software upload is unsuccessful.
... there is no communication between the
control panel and motherboard. This readout
appears briefly when switching on the fixture.
... the fixture detects the lamp is ON but no
'Lamp ON' command has been received. This
can occur if the lamp relay is stuck or if the
lamp-power feedback circuit fails. The fixture
may be operated but remote lamp on/off may
be affected.
...there is a malfunction in the temperature
sensing circuit.
...there is a malfunction in the optical pan/tilt
monitoring circuit (e.g. sensor defective). After
a time-out, the effect in question stops in a
random position.
...there is a malfunction in the electric indexing
circuit for pan, tilt, focus or zoom. The fixture
will, after the time-out, establish a mechanical
stop, and continue to work normally.
...there is a malfunction in the
magnetic-indexing circuit (e.g. sensor
defective or magnet missing). After the
time-out, the effect in question stops in a
random position.
...there is a malfunction in the electric indexing
circuit for one of the CMY flags.
...there is an onboard RAM memory error.
...there is an onboard programming error.
Table 6: Display messages
Display messages
What to do
Wait for reset to complete.
Wait for reset to complete. Note that


you can set
to prevent accidental DMX reset
commands.
Wait a few moments.
Check that the lamp access cover is
locked in place.
Check the lamp. Check that the voltage
and frequency settings match the local
supply.
Contact Martin service personnel for
assistance.
Reload software.
Check fuses and replace accordingly.
Check that cable between control panel
and motherboard is connected
properly. Reinstall software.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Reset fixture. Contact Martin service
personnel if problem continues.
Reset fixture. Contact Martin service
personnel if problem continues.
Reset fixture. Contact Martin service
personnel if problem continues.
Reset fixture. Contact Martin service
personnel if problem continues.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.

to